LC-MS/MS quantification of endogenous taurine in plasma and urine using surrogate matrix calibration and background subtraction: Application to renal transporter phenotyping
Journal of Pharmaceutical and Biomedical Analysis · 2027
DOI: 10.1016/j.jpba.2026.117704 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2027. Verfasst von Kathley Lanna Rezende de Azevedo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Analysis, Food Science and Toxicology, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão …. Hauptthemen laut MEDLINE: Taurine, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Kidney. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de São Paulo.
Abstract (Originalsprache)
Taurine is an abundant endogenous amino acid-related compound involved in several physiological processes, including osmoregulation, antioxidative defense, and cytoprotection. Its quantification in biological matrices is analytically challenging due to its high polarity, endogenous background levels, and the absence of a true blank biological matrix. In addition, taurine has emerged as a potential endogenous biomarker for renal transporter phenotyping, particularly for organic anion transporters 1 and 3 (OAT1/3). In this study, a rapid and robust LC-MS/MS method was developed and validated for the quantification of endogenous taurine in human plasma and urine using surrogate matrix calibration combined with background subtraction. Chromatographic separation was achieved on a Luna NH₂ 100 Å column (5 µm, 150 × 4.6 mm) with a total run time of 5.5 min. Calibration curves prepared in 2% bovine serum albumin and diluted urine were linear over concentration ranges of 0.05-50 µg/mL and 0.05-100 µg/mL, respectively (r² > 0.99). Precision and accuracy met regulatory acceptance criteria (≤15%, or ≤20% at the lower limit of quantification). No significant matrix effects were observed across independent plasma and urine sources, including lipemic and hemolyzed plasma samples. Matrix and dilutional parallelism were confirmed, and taurine remained stable under all tested conditions. The method was successfully applied to clinical plasma and urine samples, enabling taurine pharmacokinetic profiling and renal clearance estimation. This validated LC-MS/MS assay provides a reliable analytical platform for taurine quantification in biological matrices and supports future pharmacokinetic, biomarker, nutritional, and transporter phenotyping studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Analysis, Food Science and Toxicology, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
- Department of Pharmacy, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil.
- Department of Obstetrics and Gynecology, Ribeirão Preto Medical Schoo, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
- Department of Clinical Analysis, Food Science and Toxicology, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. Electronic address: joaopaulo.ximenez@usp.br.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação de Amparo à Pesquisa do Estado de São Paulo
Zitieren
APA
Rezende de Azevedo, K. L., Pego, Á. M. G., Rocha, A., de Lima Benzi, J. R., Pereira Dos Santos Melli, P., Cavalli, R. C., Duarte, G., Lanchote, V. L., & Ximenez, J. P. B. (2027). LC-MS/MS quantification of endogenous taurine in plasma and urine using surrogate matrix calibration and background subtraction: Application to renal transporter phenotyping. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2026.117704
Vancouver
Rezende de Azevedo KL, Pego ÁMG, Rocha A, de Lima Benzi JR, Pereira Dos Santos Melli P, Cavalli RC, et al. LC-MS/MS quantification of endogenous taurine in plasma and urine using surrogate matrix calibration and background subtraction: Application to renal transporter phenotyping. Journal of Pharmaceutical and Biomedical Analysis. 2027. doi:10.1016/j.jpba.2026.117704
BibTeX
@article{RezendedeAzevedo2027,
author = {Rezende de Azevedo, Kathley Lanna and Pego, Álef Machado Gomes and Rocha, Adriana and de Lima Benzi, Jhohann Richard and Pereira Dos Santos Melli, Patrícia and Cavalli, Ricardo Carvalho and Duarte, Geraldo and Lanchote, Vera Lucia and Ximenez, João Paulo Bianchi},
title = {LC-MS/MS quantification of endogenous taurine in plasma and urine using surrogate matrix calibration and background subtraction: Application to renal transporter phenotyping},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2027},
doi = {10.1016/j.jpba.2026.117704}
}
EUVIMED