Forced degradation study of abacavir using the electrochemistry-mass spectrometry setup
Journal of Pharmaceutical and Biomedical Analysis · 2026
DOI: 10.1016/j.jpba.2026.117679 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Filip Vymyslický und 3 weiteren Autor:innen. Beteiligte Einrichtung: Charles University, Faculty of Science, Department of Analytical Chemistry, Hlavova 2030/8, Prague 128 00, Czech Republic. Hauptthemen laut MEDLINE: Dideoxynucleosides, Electrochemical Techniques. Die Arbeit nennt 18 Literaturangaben. Gefördert von: Central European Exchange Program for University Studies, Czech Science Foundation, Charles University.
Abstract (Originalsprache)
This article investigates the electrochemical oxidation of abacavir using a simple online setup, coupling an electrochemical flow cell with a mass spectrometer, as an alternative approach to forced oxidative degradation studies. Electrochemical oxidation of abacavir was performed on a glassy carbon electrode in only 3 min, using four different solvents: three containing 0.5 mol/L ammonium acetate, pH 7.0, with 0, 50, and 90% (v/v) methanol, and one containing 0.1 mol/L NaClO4 in pure methanol. A total of seven degradation products were observed, with detector signals in different ratios depending on the solvent used. The results obtained in the EC-MS setup were compared with offline electrooxidation in static mode, performed for 5 h on the same working electrode, at the same potential, and in the same solvents as the oxidation in the EC-MS setup. The offline degraded samples were analyzed by HPLC with UV/VIS and MS detection. Of the seven monitored degradation products, six were observed in the offline mode. The abundance of individual signals was compared between the two approaches. The vast majority of degradation products were identical in both methods, and the most abundant ones were also in agreement. The study thus shows that, keeping in mind certain limitations in comparing the data, the online EC-MS approach can be used as a fast and simple indicative method for rapid screening of drug stability and susceptibility to oxidative degradation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Charles University, Faculty of Science, Department of Analytical Chemistry, Hlavova 2030/8, Prague 128 00, Czech Republic.
- Zentiva Group, a.s. U Kabelovny 130, Prague 102 37, Czech Republic.
- Charles University, Faculty of Science, Department of Analytical Chemistry, Hlavova 2030/8, Prague 128 00, Czech Republic. Electronic address: tomas.krizek@natur.cuni.cz.
Förderung
- Central European Exchange Program for University Studies
- Czech Science Foundation
- Charles University
Zitieren
APA
Vymyslický, F., Fischer, J., Heřt, J., & Křížek, T. (2026). Forced degradation study of abacavir using the electrochemistry-mass spectrometry setup. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2026.117679
Vancouver
Vymyslický F, Fischer J, Heřt J, Křížek T. Forced degradation study of abacavir using the electrochemistry-mass spectrometry setup. Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2026.117679
BibTeX
@article{Vymyslick2026,
author = {Vymyslický, Filip and Fischer, Jan and Heřt, Jakub and Křížek, Tomáš},
title = {Forced degradation study of abacavir using the electrochemistry-mass spectrometry setup},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2026},
doi = {10.1016/j.jpba.2026.117679}
}
EUVIMED