EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Optimization and clinical validation of a simplified workflow for renin-angiotensin-aldosterone system hormones and adrenal steroids: Addressing pre-analytical variability and operational efficiency

Jian Hu, Yanfen Ma, Xiaoqian Wang, Yanrong Su, Xiaofen Yuan, Lanchun Wang, William Wu, Xiaoqin Wang

Journal of Pharmaceutical and Biomedical Analysis · 2026

DOI: 10.1016/j.jpba.2026.117672 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Jian Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Laboratory, First Affiliated Hospital of Xi'an Jiaotong University, 277 Yanta West Road (P.O. 710061), Yanta District, Xi'an City, Shaanxi P…. Hauptthemen laut MEDLINE: Renin-Angiotensin System, Renin, Aldosterone, Adrenal Cortex Hormones. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is widely used for quantifying renin-angiotensin-aldosterone system (RAAS) hormones and adrenal steroids. However, pre-analytical factors frequently compromise analyte stability and measurement accuracy. This study evaluated the stability of key RAAS-related analytes under routine pre-analytical conditions, optimized a fixed-baseline calculation for plasma renin activity (PRA), and validated a simplified protocol for clinical adoption. This three-phase study comprised: a discovery cohort (n = 2661) to optimize the fixed pre-incubation angiotensin I (Ang I) baseline value; a stability study using blood samples from 40 healthy volunteers, in which analyte stability was evaluated in whole blood before centrifugation (4 ℃ or 25 ℃, 0-8 h) and in plasma after centrifugation (4 ℃, 24-72 h; -20 ℃, 15 days; or three freeze-thaw cycles at -80 ℃); and a validation cohort (n = 1230) to assess the clinical reclassification rate of aldosterone-to-renin ratio (ARR). For PRA, the pre-incubation Ang I baseline was fixed at a value determined through sensitivity optimization in the discovery cohort. Storage conditions markedly affected Ang I stability, while steroid analytes remained unchanged. Whole blood samples met acceptance criteria for up to 4 h at 25 ℃ or 8 h at 4 ℃ prior to centrifugation. After centrifugation, plasma samples remained stable for up to 24 h at 4 ℃, 15 days at -20 ℃, or after three freeze-thaw cycles at -80 ℃. The simplified PRA model showed excellent concordance with the measured values (R² = 0.999) and negligible bias in Bland-Altman analysis. This approach resulted in minimal reclassification of ARR results (0.16%, 2/1230), with all discordant cases located near the screening cut-off. This study establishes practical stability limits for RAAS-related analytes and supports a simplified PRA calculation method. This standardized approach minimizes pre-analytical variability and enhances laboratory efficiency without compromising clinical diagnostic integrity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renin-Angiotensin SystemReninAldosteroneAdrenal Cortex HormonesHumansTandem Mass SpectrometryMaleAngiotensin IReproducibility of ResultsLiquid Chromatography-Mass SpectrometryWorkflowFemaleAdultMiddle AgedCohort Studies

Stichwörter der Autor:innen

Angiotensin IHormone stabilityLiquid chromatography-tandem mass spectrometryRenin ActivityRenin-Angiotensin-Aldosterone System

Substanzen

ReninAldosteroneAngiotensin IAdrenal Cortex Hormones

Autor:innen und Institutionen

  • Clinical Laboratory, First Affiliated Hospital of Xi'an Jiaotong University, 277 Yanta West Road (P.O. 710061), Yanta District, Xi'an City, Shaanxi Province, PR China.
  • Calibra Scientific, Inc. Key Laboratory of Digital Technology in Medical Diagnostics of Zhejiang Province, Hangzhou, Zhejiang, PR China.
  • Calibra Scientific, Inc. Key Laboratory of Digital Technology in Medical Diagnostics of Zhejiang Province, Hangzhou, Zhejiang, PR China. Electronic address: weijia.wu@calibradx.com.
  • Clinical Laboratory, First Affiliated Hospital of Xi'an Jiaotong University, 277 Yanta West Road (P.O. 710061), Yanta District, Xi'an City, Shaanxi Province, PR China. Electronic address: wxq1493722680@xjtufh.edu.cn.

Zitieren

APA

Hu, J., Ma, Y., Wang, X., Su, Y., Yuan, X., Wang, L., Wu, W., & Wang, X. (2026). Optimization and clinical validation of a simplified workflow for renin-angiotensin-aldosterone system hormones and adrenal steroids: Addressing pre-analytical variability and operational efficiency. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2026.117672

Vancouver

Hu J, Ma Y, Wang X, Su Y, Yuan X, Wang L, et al. Optimization and clinical validation of a simplified workflow for renin-angiotensin-aldosterone system hormones and adrenal steroids: Addressing pre-analytical variability and operational efficiency. Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2026.117672

BibTeX
@article{Hu2026,
  author = {Hu, Jian and Ma, Yanfen and Wang, Xiaoqian and Su, Yanrong and Yuan, Xiaofen and Wang, Lanchun and Wu, William and Wang, Xiaoqin},
  title = {Optimization and clinical validation of a simplified workflow for renin-angiotensin-aldosterone system hormones and adrenal steroids: Addressing pre-analytical variability and operational efficiency},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  doi = {10.1016/j.jpba.2026.117672}
}
Kostenlos starten →