EUVIMEDEUVIMED entdecken
Validierungsstudie

Application of liquid chromatography with tandem mass spectrometry detection for the determination of twelve cannabinoids in a feasibility study to produce a pharmacologically active ingredient from seized Cannabis sativa L. (marijuana)

Rafael Scorsatto Ortiz, Danilo Pereira, Kristiane de Cassia Mariotti, Flavio Anastacio de Oliveira Camargo

Journal of Pharmaceutical and Biomedical Analysis · 2026

DOI: 10.1016/j.jpba.2026.117665 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Rafael Scorsatto Ortiz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Rio Grande do Sul Superintendence, Brazilian Federal Police, Porto Alegre, RS, Brazil; Posgraduate Program in Forensic Sciences, Federal University o…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Cannabinoids, Cannabis. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Finep.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for Cannabis-derived medicinal products in Brazil, coupled with the implementation of RDC 1013/2026 (ANVISA), necessitates robust analytical frameworks for pharmacological and forensic purposes. This study is part of the "Paracelsus Project," a feasibility study evaluating the production of plant-based active pharmaceutical ingredients (API) from seized Cannabis sativa L. (marijuana), aiming to repurpose material that is currently incinerated. Preliminary data suggests this seized material contained a total of roughly 25 tons of CBD. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of twelve phytocannabinoids (CBD, D9-THC, D8-THC, CBC, CBL, CBN, CBG, THCV, CBDV, CBDVA, CBGA, and THCA). The methodology utilized a triple quadrupole (QQQ) analyzer in positive ionization mode, designed to overcome the challenges of complex plant matrices and chemical isomers. The method achieved successful baseline separation of critical pairs, such as CBD/CBG and D9-THC/D8-THC, in under eight minutes. This analytical workflow was successfully applied to monitor cannabinoid concentrations during the extraction and purification processes from seized marijuana by Brazilian Federal Police. The validated LC-MS/MS method provides the necessary sensitivity and specificity for both quality control in API production and forensic standardization. By establishing a technical foundation for characterizing medicinal extracts and ensuring compliance with the 0.3% THC statutory threshold, this research supports public health safety and the potential for a sustainable pharmaceutical supply chain from seized materials in Brazil.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryCannabinoidsCannabisLiquid Chromatography-Mass SpectrometryFeasibility StudiesBrazilReproducibility of ResultsBulk DrugsChromatography, Liquid

Stichwörter der Autor:innen

LC-MS/MSMethod validationPhytocannabinoidsSeized Cannabis

Substanzen

CannabinoidsBulk Drugs

Autor:innen und Institutionen

  • Rio Grande do Sul Superintendence, Brazilian Federal Police, Porto Alegre, RS, Brazil; Posgraduate Program in Forensic Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil; Brazilian National Inst…
  • Inonovatox Análises e Pesquisas, Paulínia, SP, Brazil.
  • Rio Grande do Sul Superintendence, Brazilian Federal Police, Porto Alegre, RS, Brazil; Brazilian National Institute of Forensic Science and Technology, INCT FORENSE, Porto Alegre, RS, Brazil.
  • Posgraduate Program in Forensic Sciences, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil; Brazilian National Institute of Forensic Science and Technology, INCT FORENSE, Porto Alegre, RS, Brazil.

Förderung

  • Finep

Zitieren

APA

Ortiz, R. S., Pereira, D., de Cassia Mariotti, K., & de Oliveira Camargo, F. A. (2026). Application of liquid chromatography with tandem mass spectrometry detection for the determination of twelve cannabinoids in a feasibility study to produce a pharmacologically active ingredient from seized Cannabis sativa L. (marijuana). Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2026.117665

Vancouver

Ortiz RS, Pereira D, de Cassia Mariotti K, de Oliveira Camargo FA. Application of liquid chromatography with tandem mass spectrometry detection for the determination of twelve cannabinoids in a feasibility study to produce a pharmacologically active ingredient from seized Cannabis sativa L. (marijuana). Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2026.117665

BibTeX
@article{Ortiz2026,
  author = {Ortiz, Rafael Scorsatto and Pereira, Danilo and de Cassia Mariotti, Kristiane and de Oliveira Camargo, Flavio Anastacio},
  title = {Application of liquid chromatography with tandem mass spectrometry detection for the determination of twelve cannabinoids in a feasibility study to produce a pharmacologically active ingredient from seized Cannabis sativa L. (marijuana)},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  doi = {10.1016/j.jpba.2026.117665}
}
Kostenlos starten →