EUVIMEDEUVIMED entdecken
Crossref

Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS

Weifeng Li, Ka Luo, Hou Qian, Yike Wu, Yufan Wu, Yao Gao, Dayong Gu

Journal of Pharmaceutical and Biomedical Analysis · 2026

DOI: 10.1016/j.jpba.2026.117440 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Weifeng Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Shenzhen Second People's Hospital/the First Affiliated Hospital of Shenzhen University, Shenzhen 518035, China. El…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Vitamins, Water. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Fujian Medical University, Shenzhen Science and Technology Innovation Committee, Shenzhen Science and Technology Innovation Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the benchmark platform for multiplex vitamin quantification, yet simultaneous determination of chemically disparate fat-soluble (FSVs) and water-soluble vitamins (WSVs) remains analytically challenging. We introduce a pragmatic dual-stream workflow that converts the intrinsic waste segments of any LC gradient into productive analytical time, delivering complete FSV and WSV profiles. Two 5-min chromatographic separations, optimized for fat-soluble and water-soluble vitamins respectively, are staggered through a six-port divert valve: while one column eluted its analytes to the mass spectrometer, the other was shunted to waste. This seamless overlap effectively doubles the throughput within 5 min. And every WSV elution window remained fully enclosed within the waste segment of the FSV gradient, with CVs < 10 % for the internal-standard peak areas across both vitamin classes. Moreover, method comparison between dual LC-MS/MS and single LC-MS/MS across twenty patient sera yielded Spearman's rho values ranging from 0.950 to 0.997, Passing-Bablok slopes spanning 0.884-1.128, and Bland-Altman biases below 8.3 %, confirming clinical concordance. Owing to its simple equipment requirements and setup process, this method should be highly accessible for other laboratories.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryVitaminsWaterHumansSolubilityFatsChromatography, Liquid

Stichwörter der Autor:innen

Dual LC-MS/MSFat- and Water-Soluble VitaminsSimultaneous quantificationValve-mediated Switching

Substanzen

VitaminsWaterFats

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Shenzhen Second People's Hospital/the First Affiliated Hospital of Shenzhen University, Shenzhen 518035, China. Electronic address: weifengli@email.szu.edu.cn.
  • Guanlan Subdistrict Community Health Service Center, Shenzhen Longhua District Central Hospital, Shenzhen 518110, China.
  • Department of Laboratory Medicine, Shenzhen Second People's Hospital/the First Affiliated Hospital of Shenzhen University, Shenzhen 518035, China.
  • The School of Medical Technology and Engineering, Fujian Medical University, Fuzhou 350122, China. Electronic address: yaogao@fjmu.edu.cn.
  • Department of Laboratory Medicine, Shenzhen Second People's Hospital/the First Affiliated Hospital of Shenzhen University, Shenzhen 518035, China. Electronic address: wanhood@163.com.

Förderung

  • Fujian Medical University
  • Shenzhen Science and Technology Innovation Committee
  • Shenzhen Science and Technology Innovation Program
  • Science and Technology Planning Project of Guangdong Province

Zitieren

APA

Li, W., Luo, K., Qian, H., Wu, Y., Wu, Y., Gao, Y., & Gu, D. (2026). Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2026.117440

Vancouver

Li W, Luo K, Qian H, Wu Y, Wu Y, Gao Y, et al. Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS. Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2026.117440

BibTeX
@article{Li2026,
  author = {Li, Weifeng and Luo, Ka and Qian, Hou and Wu, Yike and Wu, Yufan and Gao, Yao and Gu, Dayong},
  title = {Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  doi = {10.1016/j.jpba.2026.117440}
}
Kostenlos starten →