EUVIMEDEUVIMED entdecken
Crossref

Electrochemical sensors based on graphene/silver sulfide nanocomposites for the indirect detection of mercury sulfide in the Tibetan medicine “Zuo Tai”

Rongfeng Kang, Xiaoping Bai, Delai Zhou, Cong Tang, Xin Wang, Jiayu Xi, Shijun Shao, Shuqing Dong, Fude Yang

Journal of Pharmaceutical and Biomedical Analysis · 2026

DOI: 10.1016/j.jpba.2025.117318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Rongfeng Kang und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Pharmacy, Gansu University of Chinese Medicine, Lanzhou, Gansu 730000, PR China. Hauptthemen laut MEDLINE: Graphite, Nanocomposites, Electrochemical Techniques, Mercury Compounds. Die Arbeit nennt 49 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mercury sulfide (HgS) is one of the primary constituents of the Tibetan medicine "Zuo Tai," and its content directly impacts the drug's efficacy and safety. Therefore, developing rapid, direct, and highly sensitive detection methods is of significant importance. In this study, a novel electrochemical sensor based on graphene/silver sulfide (G/Ag2S) nanocomposites was developed for the rapid detection of HgS in Tibetan medicine "Zuo Tai." The G/Ag2S nanocomposite was prepared using the hydrothermal synthesis method. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analysis indicated that the G/Ag2S nanocomposite enhanced the electrochemical signal response and improved the electrochemical activity of the glassy carbon electrode (GCE) after modification. Under optimized conditions, linear detection of HgS was achieved using differential pulse voltammetry (DPV). The DPV oxidation peak current decreased with increasing HgS concentration due to its adsorption onto the G/Ag2S-modified electrode, which altered the redox properties. The detection range of this analytical method was 0.1-10 mg/L, with a detection limit of 0.0194 mg/L. Further studies revealed that the modified electrode prepared in this paper exhibited excellent selectivity toward HgS. When detecting the HgS content in the "Zuo Tai" sample, the sensor demonstrated high sensitivity, with an average HgS content of 54.38 % in the sample and a relative standard deviation (RSD) of 1.07 %, consistent with the results reported in the literature. This analytical method provides a rapid and reliable quality control method for traditional medicines containing HgS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteNanocompositesElectrochemical TechniquesMercury CompoundsSilver CompoundsMedicine, Tibetan TraditionalLimit of DetectionElectrodesDielectric Spectroscopy

Stichwörter der Autor:innen

Electrochemical sensorsG/Ag(2)S electrodesHgSTibetan medicine “Zuo Tai”

Substanzen

GraphiteMercury CompoundsSilver Compoundssilver sulfidecinnabar

Autor:innen und Institutionen

  • College of Pharmacy, Gansu University of Chinese Medicine, Lanzhou, Gansu 730000, PR China.
  • Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, PR China.
  • School of Chemical Engineering, Northwest Minzu University, Lanzhou, Gansu 730030, China.
  • Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, PR China. Electr…
  • College of Pharmacy, Gansu University of Chinese Medicine, Lanzhou, Gansu 730000, PR China. Electronic address: gszyyfd@163.com.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Kang, R., Bai, X., Zhou, D., Tang, C., Wang, X., Xi, J., Shao, S., Dong, S., & Yang, F. (2026). Electrochemical sensors based on graphene/silver sulfide nanocomposites for the indirect detection of mercury sulfide in the Tibetan medicine “Zuo Tai”. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2025.117318

Vancouver

Kang R, Bai X, Zhou D, Tang C, Wang X, Xi J, et al. Electrochemical sensors based on graphene/silver sulfide nanocomposites for the indirect detection of mercury sulfide in the Tibetan medicine “Zuo Tai”. Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2025.117318

BibTeX
@article{Kang2026,
  author = {Kang, Rongfeng and Bai, Xiaoping and Zhou, Delai and Tang, Cong and Wang, Xin and Xi, Jiayu and Shao, Shijun and Dong, Shuqing and Yang, Fude},
  title = {Electrochemical sensors based on graphene/silver sulfide nanocomposites for the indirect detection of mercury sulfide in the Tibetan medicine “Zuo Tai”},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  doi = {10.1016/j.jpba.2025.117318}
}
Kostenlos starten →