EUVIMEDEUVIMED entdecken
Validierungsstudie

Development and validation of an LC-Orbitrap-HRMS method for quantification of human insulin and selected insulin analogues with application on two forensic cases

Yu Zhonghao, Yuan Yuhao, Zhang Jiaxin, Tao Jing, Gao Hang, Gao Xiangting, Zhou Yiwu

Journal of Pharmaceutical and Biomedical Analysis · 2026

DOI: 10.1016/j.jpba.2025.117282 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026. Verfasst von Yu Zhonghao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China. Hauptthemen laut MEDLINE: Insulin. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Insulin, a peptide hormone essential for blood glucose regulation, is typically quantified in clinical practice using immunoassays. While sensitive, these assays lack specificity and are often inadequate for the precise qualification and quantification in forensic practices. To address this limitation, we developed and validated an LC-Orbitrap-HRMS method for the quantification of intact insulin and its analogues in four postmortem matrices: plasma, liver, kidney, and adipose tissue. Method validation demonstrated linearity for human insulin in plasma from 0.1 to 100 ng/mL, with accuracy between 90.1 % and 106.9 %. Notably, in challenging matrices such as adipose tissue, the LLOQ was 1 ng/mL, with accuracy range from 94.1 % to 100.2 %, confirming robust analytical performance. The validated method was applied on two forensic cases involving suspected insulin overdose. Insulin concentrations in subcutaneous adipose tissue from the injection sites were significantly elevated, measuring 743.1 ng/mL and 53.2 ng/mL, respectively. These results demonstrate the utility of the method in providing reliable evidence for the investigation of suspected fatal insulin intoxication.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InsulinHumansAdipose TissueChromatography, LiquidDrug OverdoseForensic ToxicologyHypoglycemic AgentsKidneyLimit of DetectionLiverReproducibility of ResultsTandem Mass Spectrometry

Stichwörter der Autor:innen

Forensic toxicologyInsulin overdoseLC-Orbitrap-HRMSMethod validation

Substanzen

Hypoglycemic AgentsInsulin

Autor:innen und Institutionen

  • Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
  • Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
  • Huangshi Public Security Bureau, Huangshi 435000, China. Electronic address: 274843208@qq.com.
  • Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China; First Affiliated Hospital, Shihezi University/Department of Pathology and Key Laboratory for X…
  • Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China. Electronic address: zhouyiwu@hust.edu.cn.

Zitieren

APA

Zhonghao, Y., Yuhao, Y., Jiaxin, Z., Jing, T., Hang, G., Xiangting, G., & Yiwu, Z. (2026). Development and validation of an LC-Orbitrap-HRMS method for quantification of human insulin and selected insulin analogues with application on two forensic cases. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2025.117282

Vancouver

Zhonghao Y, Yuhao Y, Jiaxin Z, Jing T, Hang G, Xiangting G, et al. Development and validation of an LC-Orbitrap-HRMS method for quantification of human insulin and selected insulin analogues with application on two forensic cases. Journal of Pharmaceutical and Biomedical Analysis. 2026. doi:10.1016/j.jpba.2025.117282

BibTeX
@article{Zhonghao2026,
  author = {Zhonghao, Yu and Yuhao, Yuan and Jiaxin, Zhang and Jing, Tao and Hang, Gao and Xiangting, Gao and Yiwu, Zhou},
  title = {Development and validation of an LC-Orbitrap-HRMS method for quantification of human insulin and selected insulin analogues with application on two forensic cases},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  doi = {10.1016/j.jpba.2025.117282}
}
Kostenlos starten →