EUVIMEDEUVIMED entdecken
Crossref

Point-of-care fentanyl detection: Combining smartphone imaging and chemometrics for reliable quantitative analysis

Yasaman Sefid-Sefidehkhan, Mohammad Hasanzadeh, Abolghasem Jouyban, Sedigheh Mohammadzadeh, Mohamadbahger Hosseini, Vahid Jouyban-Gharamaleki, Elaheh Rahimpour

Journal of Pharmaceutical and Biomedical Analysis · 2026-03 · 270 · 117277

DOI: 10.1016/j.jpba.2025.117277 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2026-03. Verfasst von Yasaman Sefid-Sefidehkhan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran. Hauptthemen laut MEDLINE: Fentanyl, Smartphone, Point-of-Care Systems, Chemometrics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Iran National Science Foundation, National Institute for Medical Research Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, the possibility of using smartphone image analysis in combination with the spot test as a quick and simple method of fentanyl analysis was investigated. A probe composed of silver nanoprism-graphene quantum dots (AgNprs-GQD) has been used to induce color variations at different fentanyl concentrations. The data for these variations were recorded by spectrophotometry, spectrofluorimetry, and the digital image colorimetry methodology for comparison. Image analysis was achieved using the PhotoMetrix smartphone App, which uses univariate calibration of the collected images. For further investigation of image analysis, multivariate calibration was performed using the parallel factor analysis (PARAFAC) method in the MATLAB environment. The method was validated by comparing the results obtained from the image analysis methods and spectrophotometry as a standard method. Under optimized conditions, linear ranges and limits of detection (LOD) were 0.001- 0.3 µg/mL and 0.0007 µg/mL for the spectrophotometry method, 0.01- 0.5 µg/mL and 0.009 µg/mL for the spectrofluorimetry method, 0.001- 3.0 µg/mL and 0.0008 µg/mL for the smartphone colorimetry method, and 0.001- 0.5 µg/mL and 0.0007 µg/mL for PARAFAC. Intra-day and inter-day precisions were obtained at ≤ 6.4 % and ≤ 10.8 %. The method was successfully applied to exhaled breath condensate samples from ventilated neonates, demonstrating a non-invasive, rapid, and field-deployable approach for point-of-care fentanyl quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FentanylSmartphonePoint-of-Care SystemsChemometricsHumansLimit of DetectionQuantum DotsColorimetrySilverSpectrometry, FluorescenceGraphiteCalibrationReproducibility of ResultsSpectrophotometryMetal Nanoparticles

Stichwörter der Autor:innen

ColorimetryDigital imageExhaled breath condensateFentanylSmartphone

Substanzen

FentanylSilverGraphite

Autor:innen und Institutionen

  • Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran; Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Pediatric Health Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Kimia Idea Pardaz Azarbayjan (KIPA) Science Based Company, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address: rahimpour@tbzmed.ac.ir.

Förderung

  • Iran National Science Foundation
  • National Institute for Medical Research Development

Zitieren

APA

Sefid-Sefidehkhan, Y., Hasanzadeh, M., Jouyban, A., Mohammadzadeh, S., Hosseini, M., Jouyban-Gharamaleki, V., & Rahimpour, E. (2026). Point-of-care fentanyl detection: Combining smartphone imaging and chemometrics for reliable quantitative analysis. Journal of Pharmaceutical and Biomedical Analysis, 270, 117277. https://doi.org/10.1016/j.jpba.2025.117277

Vancouver

Sefid-Sefidehkhan Y, Hasanzadeh M, Jouyban A, Mohammadzadeh S, Hosseini M, Jouyban-Gharamaleki V, et al. Point-of-care fentanyl detection: Combining smartphone imaging and chemometrics for reliable quantitative analysis. Journal of Pharmaceutical and Biomedical Analysis. 2026;270:117277. doi:10.1016/j.jpba.2025.117277

BibTeX
@article{SefidSefidehkhan2026,
  author = {Sefid-Sefidehkhan, Yasaman and Hasanzadeh, Mohammad and Jouyban, Abolghasem and Mohammadzadeh, Sedigheh and Hosseini, Mohamadbahger and Jouyban-Gharamaleki, Vahid and Rahimpour, Elaheh},
  title = {Point-of-care fentanyl detection: Combining smartphone imaging and chemometrics for reliable quantitative analysis},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2026},
  volume = {270},
  pages = {117277},
  doi = {10.1016/j.jpba.2025.117277}
}
Kostenlos starten →