Affinity-based 3D-printed microfluidic chip for clinical sepsis detection with CD69, CD64, and CD25
Journal of Pharmaceutical and Biomedical Analysis · 2025
DOI: 10.1016/j.jpba.2024.116500 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2025. Verfasst von Kitiara Griffin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409, USA. Hauptthemen laut MEDLINE: Sepsis, Lectins, C-Type, Antigens, Differentiation, T-Lymphocyte, Antigens, CD. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Institutes of Health, National Institute of General Medical Sciences.
Themen: Sepsis
Abstract (Originalsprache)
Sepsis is a life-threatening immune response to infection in the body, eventually resulting in fatal organ failure. Current methods utilize blood cultures and quick-Sequential-Organ-Failure-Assessment (qSOFA), but there is a need for more accurate and time-sensitive diagnostic methods to improve survival rates. We present a 3D-printed microfluidic chip that bioconjugates antibodies CD69, CD64, and CD25 to channel surfaces to capture sepsis cells in blood samples and validate it with clinical samples (n = 125 septic, n = 10 healthy). Other variables were taken such as healthy volunteer blood samples and patient demographics to validate and confirm our device's diagnostic ability. Statistical differences were found between healthy volunteer and sepsis patient antigen cell counts (CD69 p-value < 0.001, CD64 p-value < 0.004, CD25 p-value < 0.0009), and were confirmed using principal component analysis. Demographics such as length of stay, age, culture results, and need for surgery also factored into sepsis detection on a smaller scale than the antigen cell counts. The receiver operating characteristic (ROC) analysis showed an area under the curve (AUC) of 0.989, 0.988, and 0.992 for CD69, CD64, and CD25, respectively, and a combined biomarker panel of 0.997. Overall, the device performed within a shorter time frame of 4 h compared to standard blood culture tests and was validated for use in detecting sepsis in patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409, USA.
- Clinical Research Institute, Texas Tech Health Sciences Center, Lubbock, TX, USA.
- Department of Surgery, Texas Tech Health Sciences Center, Lubbock, TX, USA.
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409, USA. Electronic address: d.pappas@ttu.edu.
Förderung
- National Institutes of Health
- National Institute of General Medical Sciences
Zitieren
APA
Griffin, K., Miller, L., Yang, Y., Sharp, E., Young, L., Garcia, L., Griswold, J., & Pappas, D. (2025). Affinity-based 3D-printed microfluidic chip for clinical sepsis detection with CD69, CD64, and CD25. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116500
Vancouver
Griffin K, Miller L, Yang Y, Sharp E, Young L, Garcia L, et al. Affinity-based 3D-printed microfluidic chip for clinical sepsis detection with CD69, CD64, and CD25. Journal of Pharmaceutical and Biomedical Analysis. 2025. doi:10.1016/j.jpba.2024.116500
BibTeX
@article{Griffin2025,
author = {Griffin, Kitiara and Miller, Lindsee and Yang, Yijia and Sharp, Elizabeth and Young, Lane and Garcia, Liza and Griswold, John and Pappas, Dimitri},
title = {Affinity-based 3D-printed microfluidic chip for clinical sepsis detection with CD69, CD64, and CD25},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2025},
doi = {10.1016/j.jpba.2024.116500}
}
EUVIMED