Ocular pharmacokinetics of acetazolamide from intravitreal implants by high-performance liquid chromatography coupled to tandem mass spectrometry

Pedro Henrique Reis da Silva, Matheus Augusto de Castro, Marcela Coelho Silva Ribeiro, Eduarda Diniz Ferreira, José Eduardo Gonçalves, Gérson Antônio Pianetti, Sílvia Ligório Fialho, Armando da Silva-Cunha Júnior, Christian Fernandes

Journal of Pharmaceutical and Biomedical Analysis · 2025

DOI: 10.1016/j.jpba.2024.116458 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2025. Verfasst von Pedro Henrique Reis da Silva und 8 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Products Department, Faculty of Pharmacy, Federal University of Minas Gerais, Belo Horizonte, Brazil. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Acetazolamide, Vitreous Body. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Coordination of Higher Education Personnel Improvement, National Council for Scientific and Technological Development, Fundacao de Amparo a Pesquisa do Estado de Minas Gerais.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glaucoma, a leading cause of irreversible blindness, affects about 70 million people globally. Its treatment focuses on reducing intraocular pressure. Acetazolamide, a potent anti-glaucoma drug, is currently used only systemically due to low solubility and permeation, which cause severe side effects. Developing topical medications with acetazolamide requires robust analytical methods for its detection in biological samples. In this context, this study aimed to develop a method to quantify acetazolamide in rabbit vitreous humor samples. The method involved a simple, fast, inexpensive, and environmentally friendly protein precipitation step for sample preparation, needing just 50 μL of sample and 200 μL of organic solvent, with adequate recovery. This was combined with high-performance liquid chromatography coupled to tandem mass spectrometry, enabling highly sensitive (LOQ of 5 ng/mL) quantification within only 5 min. The method proved to be selective, precise, and accurate, with well-fitted analytical curves, with no carryover, and no matrix effect impacting reliability. The method was successfully applied to analyze vitreous humor samples from rabbits in pharmacokinetic studies, monitoring drug release from intravitreal implants. Results showed a controlled release profile, with a maximum drug concentration (Cmax) of 426.01 ± 64.57 ng/mL, time to reach Cmax (Tmax) of 28 days, and area under the curve (AUC0-42 and AUC0-∞) of 7722.66 ± 1125.96 ng days/mL and 8998.11 ± 1311.92 ng days/mL, respectively. The device demonstrated significantly slower elimination, ensuring therapeutic levels for an extended period when compared to intravitreal injection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryAcetazolamideVitreous BodyAnimalsRabbitsChromatography, High Pressure LiquidReproducibility of ResultsDrug ImplantsArea Under CurveMaleDrug LiberationCarbonic Anhydrase InhibitorsDelayed-Action Preparations

Stichwörter der Autor:innen

AcetazolamideBioanalysisCarbonic anhydrase inhibitorGlaucomaPharmacokineticsTandem mass spectrometry

Substanzen

AcetazolamideDrug ImplantsCarbonic Anhydrase InhibitorsDelayed-Action Preparations

Autor:innen und Institutionen

  • Pharmaceutical Products Department, Faculty of Pharmacy, Federal University of Minas Gerais, Belo Horizonte, Brazil.
  • Leicester School of Pharmacy, De Montfort University, Leicester, United Kingdom.
  • Pharmaceutical Research and Development, Ezequiel Dias Foundation (FUNED), Belo Horizonte, Brazil.
  • Pharmaceutical Products Department, Faculty of Pharmacy, Federal University of Minas Gerais, Belo Horizonte, Brazil. Electronic address: cfernandes@farmacia.ufmg.br.

Förderung

  • Coordination of Higher Education Personnel Improvement
  • National Council for Scientific and Technological Development
  • Fundacao de Amparo a Pesquisa do Estado de Minas Gerais

Zitieren

APA

Reis da Silva, P. H., Castro, M. A., Ribeiro, M. C. S., Ferreira, E. D., Gonçalves, J. E., Pianetti, G. A., Fialho, S. L., Júnior, A. D. S., & Fernandes, C. (2025). Ocular pharmacokinetics of acetazolamide from intravitreal implants by high-performance liquid chromatography coupled to tandem mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116458

Vancouver

Reis da Silva PH, Castro MA, Ribeiro MCS, Ferreira ED, Gonçalves JE, Pianetti GA, et al. Ocular pharmacokinetics of acetazolamide from intravitreal implants by high-performance liquid chromatography coupled to tandem mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis. 2025. doi:10.1016/j.jpba.2024.116458

BibTeX
@article{ReisdaSilva2025,
  author = {Reis da Silva, Pedro Henrique and Castro, Matheus Augusto de and Ribeiro, Marcela Coelho Silva and Ferreira, Eduarda Diniz and Gonçalves, José Eduardo and Pianetti, Gérson Antônio and Fialho, Sílvia Ligório and Júnior, Armando da Silva-Cunha and Fernandes, Christian},
  title = {Ocular pharmacokinetics of acetazolamide from intravitreal implants by high-performance liquid chromatography coupled to tandem mass spectrometry},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2025},
  doi = {10.1016/j.jpba.2024.116458}
}
Kostenlos starten →