Quantification of API content in pharmaceutical tablets within milliseconds by time-stretch near-infrared transmission spectroscopy
Journal of Pharmaceutical and Biomedical Analysis · 2024
DOI: 10.1016/j.jpba.2024.116372 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2024. Verfasst von Koji Nakayama und 8 weiteren Autor:innen. Beteiligte Einrichtung: Production Division, Manufacturing Technology Department, Towa Pharmaceutical Co., Ltd., 3-8 Matsuo, Kadoma, Osaka 571-0044, Japan. Electronic addres…. Hauptthemen laut MEDLINE: Tablets, Spectroscopy, Near-Infrared. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Agency for Medical Research and Development.
Abstract (Originalsprache)
We explored the feasibility of high-speed and high-accuracy quantification of active pharmaceutical ingredient (API) content in tablet products by near-infrared (NIR) spectroscopy to improve the reliability of pharmaceuticals. For this purpose, we employed a high-power NIR time-stretch transmission spectrometer recently developed by us. By using this transmission spectrometer with a multivariate calibration model, we demonstrated the ability to quantify API content with a short measurement time of 3.9 ms per tablet for model pharmaceuticals. For the model tablet, the quantification ability of our spectrometer was comparable to that achieved by a commonly used Fourier-transform NIR (FT-NIR) spectrometer with a measurement time of several seconds. We also confirmed that the effect of irradiating tablets with the NIR pulses used in our spectrometer was negligible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Production Division, Manufacturing Technology Department, Towa Pharmaceutical Co., Ltd., 3-8 Matsuo, Kadoma, Osaka 571-0044, Japan. Electronic address: k-nakayama@towayakuhin.co.jp.
- New Technology Development Department, R&D Division, Business Creation Division, USHIO INC., 6409 Motoishikawa, Aoba, Yokohama, Kanagawa 225-0004, Japan.
- Production Division, Manufacturing Technology Department, Towa Pharmaceutical Co., Ltd., 3-8 Matsuo, Kadoma, Osaka 571-0044, Japan.
- National Institute of Health Sciences, MHLW, 3-25-26 Tonomachi, Kawasaki, Kawasaki, Kanagawa 210-9501, Japan.
Förderung
- Japan Agency for Medical Research and Development
Zitieren
APA
Nakayama, K., Sahara, J., Fujimoto, M., Yagisawa, Y., Kobata, K., Kawagoe, H., Ikarashi, A., Yokoyama, T., & Sakamoto, T. (2024). Quantification of API content in pharmaceutical tablets within milliseconds by time-stretch near-infrared transmission spectroscopy. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116372
Vancouver
Nakayama K, Sahara J, Fujimoto M, Yagisawa Y, Kobata K, Kawagoe H, et al. Quantification of API content in pharmaceutical tablets within milliseconds by time-stretch near-infrared transmission spectroscopy. Journal of Pharmaceutical and Biomedical Analysis. 2024. doi:10.1016/j.jpba.2024.116372
BibTeX
@article{Nakayama2024,
author = {Nakayama, Koji and Sahara, Junki and Fujimoto, Masaya and Yagisawa, Yasufumi and Kobata, Keiko and Kawagoe, Hiroyuki and Ikarashi, Aya and Yokoyama, Takuma and Sakamoto, Tomoaki},
title = {Quantification of API content in pharmaceutical tablets within milliseconds by time-stretch near-infrared transmission spectroscopy},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2024},
doi = {10.1016/j.jpba.2024.116372}
}
EUVIMED