Indicator displacement-based colorimetric assay for dibutyl phthalate in pharmaceutical products with titanium(IV)-pyridylazo resorcinol (PAR)
Journal of Pharmaceutical and Biomedical Analysis · 2024
DOI: 10.1016/j.jpba.2024.116323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2024. Verfasst von Ülkü Nida Çolak und 5 weiteren Autor:innen. Beteiligte Einrichtung: TEBIP High Performers Program, Board of Higher Education of Türkiye, Istanbul University, Fatih, Istanbul 34452, Türkiye. Hauptthemen laut MEDLINE: Colorimetry, Resorcinols, Titanium, Dibutyl Phthalate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: TÜBİTAK.
Abstract (Originalsprache)
Taking advantage of the competitive binding affinity towards Ti(IV) between 4-(2-pyridylazo) resorcinol (PAR) and phthalate, a simple indicator displacement (ID)-based colorimetric assay was designed for indirect determination of a well-known phthalic acid ester, dibutyl phthalate (DBP). The indicator PAR and Ti(IV) formed a purplish-red-colored Ti(IV)-PAR complex (λmax = 540 nm) at a 1:1 ratio. In the presence of pre-hydrolyzed DBP, colorless complex formation of phthalate ion (emerging from alkaline hydrolysis of DBP) with Ti(IV) resulted in a hypsochromic shift in absorbance maximum, accompanying a color change from purplish-red to yellowish-orange (λmax = 390 nm) by the release of PAR from Ti(IV)-PAR system. Based on this mechanism, the linear response range of the system for DBP was found to lie between 0.16 and 0.37 mmol L-1 with an experimental detection limit of 11.6 µmol L-1. The recommended Ti(IV)-PAR system was successfully applied to DBP-containing pharmaceutical products (as real sample) after a simple clean-up process for removing possible water-soluble interferents. The analytical results obtained from the recommended method (by applying the standard addition approach) and the reference liquid chromatography-tandem mass spectrometric (LC-MS/MS) method were statistically compared using DBP-extract of the drug samples. Consequently, a simple and selective colorimetric ID strategy was proposed for the analysis of DBP in pharmaceuticals for the first time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- TEBIP High Performers Program, Board of Higher Education of Türkiye, Istanbul University, Fatih, Istanbul 34452, Türkiye.
- Analytical Chemistry Division, Department of Chemistry, Faculty of Engineering, Istanbul University-Cerrahpaşa, Avcilar, Istanbul 34320, Türkiye.
- Analytical Chemistry Division, Department of Chemistry, Faculty of Engineering, Istanbul University-Cerrahpaşa, Avcilar, Istanbul 34320, Türkiye; Department of Chemistry, Institute of Graduate Studies, Istanbul Universi…
- Analytical Chemistry Division, Department of Chemistry, Faculty of Engineering, Istanbul University-Cerrahpaşa, Avcilar, Istanbul 34320, Türkiye. Electronic address: auzer@iuc.edu.tr.
- Analytical Chemistry Division, Department of Chemistry, Faculty of Engineering, Istanbul University-Cerrahpaşa, Avcilar, Istanbul 34320, Türkiye; Turkish Academy of Sciences (TUBA), Vedat Dalokay St. No: 112 Çankaya, An…
Förderung
- TÜBİTAK
Zitieren
APA
Çolak, Ü. N., Yılmaz, E., Durmazel, S., Can, K., Üzer, A., & Apak, R. (2024). Indicator displacement-based colorimetric assay for dibutyl phthalate in pharmaceutical products with titanium(IV)-pyridylazo resorcinol (PAR). Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116323
Vancouver
Çolak ÜN, Yılmaz E, Durmazel S, Can K, Üzer A, Apak R. Indicator displacement-based colorimetric assay for dibutyl phthalate in pharmaceutical products with titanium(IV)-pyridylazo resorcinol (PAR). Journal of Pharmaceutical and Biomedical Analysis. 2024. doi:10.1016/j.jpba.2024.116323
BibTeX
@article{olak2024,
author = {Çolak, Ülkü Nida and Yılmaz, Elif and Durmazel, Selen and Can, Kader and Üzer, Ayşem and Apak, Reşat},
title = {Indicator displacement-based colorimetric assay for dibutyl phthalate in pharmaceutical products with titanium(IV)-pyridylazo resorcinol (PAR)},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2024},
doi = {10.1016/j.jpba.2024.116323}
}
EUVIMED