EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Impact of three different peak picking software tools on the quality of untargeted metabolomics data

Yannick Wartmann, Martina I Boxler, Thomas Kraemer, Andrea E Steuer

Journal of Pharmaceutical and Biomedical Analysis · 2024

DOI: 10.1016/j.jpba.2024.116302 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2024. Verfasst von Yannick Wartmann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine,University of Zurich, Winterthurerstrasse 190/52, Zurich 80…. Hauptthemen laut MEDLINE: Software, Metabolomics. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data quality and control parameters are becoming more important in metabolomics. For peak picking, open-source or commercial solutions are used. Other publications consider different software solutions or data acquisition types for peak picking, a combination, including proposed and new quality parameters for the process of peak picking, does not exist. This study tries to examine the performance of three different software in terms of reproducibility and quality of their output while also considering new quality parameters to gain a better understanding of resulting feature lists in metabolomics data. We saw best recovery of spiked analytes in MS-DIAL. Reproducibility over multiple projects was good among all software. The total number of features found was consistent for DDA and full scan acquisition in MS-DIAL but full scan data leading to considerably more features in MZmine and Progenesis Qi. Feature linearity proved to be a good quality parameter. Features in MS-DIAL and MZmine, showed good linearity while Progenesis Qi produced large variation, especially in full scan data. Peak width proved to be a very powerful filtering criteria revealing many features in MZmine and Progenesis Qi to be of questionable peak width. Additionally, full scan data appears to produce a disproportionally higher number of short features. This parameter is not yet available in MS-DIAL. Finally, the manual classification of true positive features proved MS-DIAL to perform significantly better in DDA data (62 % true positive) than the two other software in either mode. We showed that currently popular solutions MS-DIAL and MZmine perform well in targeted analysis of spiked analytes as well as in classic untargeted analysis. The commercially available solution Progenesis Qi does not hold any advantage over the two in terms of quality parameters, of which we proposed peak width as a new parameter and showed that already proposed parameters such as feature linearity in samples of increasing concentration are advisable to use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SoftwareMetabolomicsReproducibility of ResultsQuality Control

Stichwörter der Autor:innen

(Un)targeted metabolomicsComparisonDDADIALC-MS/MSMS-DIALMZmine

Autor:innen und Institutionen

  • Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine,University of Zurich, Winterthurerstrasse 190/52, Zurich 8057, Switzerland.
  • Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine,University of Zurich, Winterthurerstrasse 190/52, Zurich 8057, Switzerland. Electronic address: andrea.steuer@irm.uzh.ch.

Zitieren

APA

Wartmann, Y., Boxler, M. I., Kraemer, T., & Steuer, A. E. (2024). Impact of three different peak picking software tools on the quality of untargeted metabolomics data. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116302

Vancouver

Wartmann Y, Boxler MI, Kraemer T, Steuer AE. Impact of three different peak picking software tools on the quality of untargeted metabolomics data. Journal of Pharmaceutical and Biomedical Analysis. 2024. doi:10.1016/j.jpba.2024.116302

BibTeX
@article{Wartmann2024,
  author = {Wartmann, Yannick and Boxler, Martina I and Kraemer, Thomas and Steuer, Andrea E},
  title = {Impact of three different peak picking software tools on the quality of untargeted metabolomics data},
  journal = {Journal of Pharmaceutical and Biomedical Analysis},
  year = {2024},
  doi = {10.1016/j.jpba.2024.116302}
}
Kostenlos starten →