Comparative evaluation of liquid-liquid extraction and nanosorbent extraction for HPLC-PDA analysis of cabazitaxel from rat plasma
Journal of Pharmaceutical and Biomedical Analysis · 2024
DOI: 10.1016/j.jpba.2024.116149 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Pharmaceutical and Biomedical Analysis, 2024. Verfasst von Medapati Nikitha Lakshmi Suseela und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, UP 221005, India. Hauptthemen laut MEDLINE: Liquid-Liquid Extraction, Graphite, Solid Phase Extraction, Limit of Detection. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Department of Biotechnology Ministry of Science and Technology, Douglas Bomford Trust.
Abstract (Originalsprache)
A precise, sensitive, accurate, and validated reverse-phase high-performance liquid chromatography (RP-HPLC) method with a bioanalytical approach was utilized to analyze Cabazitaxel (CBZ) in rat plasma. Comparative research on extraction recoveries was performed between traditional liquid-liquid extraction (LLE) and synthesized graphene oxide (GO) based magnetic solid phase extraction (GO@MSPE). The superparamagnetic hybrid nanosorbent was synthesized using the combination of iron oxide and GO and subsequently applied for extraction and bioanalytical quantification of CBZ from plasma by (HPLC-PDA) analysis. Fourier- transform infrared spectroscopy (FT-IR), particle size, scanning electron microscopy (SEM), and x-ray diffraction (XRD) analysis were employed in the characterization of synthesized GO@MSPE nanosorbent. The investigation was accomplished using a shim pack C18 column (150 mm×4.6 mm, 5 µm) with a binary gradient mobile phase consisting of formic acid: acetonitrile: water (0.1:75:25, v/v/v) at a 0.8 mL/min flow rate, and a λmax of 229 nm. The limits of detection (LOD) and quantitation (LOQ) have been determined to be 50 and 100 ng/mL for both LLE and SPE techniques. The linearity range of the approach encompassed from 100 to 5000 ng/mL and was found to be linear (coefficient of determination > 0.99) for CBZ. The proposed method showed extraction recovery of 76.8-88.4% for the synthesized GO@MSPE and 69.3-77.4% for LLE, suggesting that the proposed bioanalytical approach was robust and qualified for all validation parameters within the acceptable criteria. Furthermore, the developed hybrid GO@MSPE nanosorbent with the help of the proposed RP-HPLC method, showed a significant potential for the extraction of CBZ in bioanalysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, UP 221005, India.
- Department of Pharmaceutical Science, School of Applied Sciences and Humanities, VIGNAN'S Foundation for Science, Technology & Research, Vadlamudi 522213, India.
- Department of Physics, Banaras Hindu University, Varanasi 221005, India.
- Department of Microbiology, Pondicherry University, Puducherry 605014, India.
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, UP 221005, India. Electronic address: msmuthu.phe@itbhu.ac.in.
Förderung
- Department of Biotechnology Ministry of Science and Technology
- Douglas Bomford Trust
Zitieren
APA
Suseela, M. N. L., Mehata, A. K., Vallamkonda, B., Gokul, P., Pradhan, A., Pandey, J., Selvin, J., Sterlin Leo Hudson, M., & Muthu, M. S. (2024). Comparative evaluation of liquid-liquid extraction and nanosorbent extraction for HPLC-PDA analysis of cabazitaxel from rat plasma. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2024.116149
Vancouver
Suseela MNL, Mehata AK, Vallamkonda B, Gokul P, Pradhan A, Pandey J, et al. Comparative evaluation of liquid-liquid extraction and nanosorbent extraction for HPLC-PDA analysis of cabazitaxel from rat plasma. Journal of Pharmaceutical and Biomedical Analysis. 2024. doi:10.1016/j.jpba.2024.116149
BibTeX
@article{Suseela2024,
author = {Suseela, Medapati Nikitha Lakshmi and Mehata, Abhishesh Kumar and Vallamkonda, Bhaskar and Gokul, Pathraj and Pradhan, Aditi and Pandey, Jyotsana and Selvin, Joseph and Sterlin Leo Hudson, M and Muthu, Madaswamy S},
title = {Comparative evaluation of liquid-liquid extraction and nanosorbent extraction for HPLC-PDA analysis of cabazitaxel from rat plasma},
journal = {Journal of Pharmaceutical and Biomedical Analysis},
year = {2024},
doi = {10.1016/j.jpba.2024.116149}
}
EUVIMED