EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Multicenter retrospective study on the efficacy of reconstruction using a polished taper cemented stem for periprosthetic femoral fractures following total hip arthroplasty and hemiarthroplasty

Masaru Kadowaki, Hiroshi Fujita, Toshiki Iwase, Hisanori Oura, Kan Sasaki, Takkan Morishima, Tatsuro Sakurai, Ryohei Takada, Yuji Uchio

Journal of Orthopaedic Science · 2026-11

DOI: 10.1016/j.jos.2026.10.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Science, 2026-11. Verfasst von Masaru Kadowaki und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Shimane University, 89-1, Enya-cho, Izumo, Shimane 693-8501, Japan. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Periprosthetic femoral fractures (PPF) after hip arthroplasty are serious, with high complication rates, poor outcomes, and increased mortality. Surgical options include osteosynthesis and revision arthroplasty, but optimal management remains controversial. This study aimed to evaluate postoperative clinical and radiological outcomes of revision hip arthroplasty using a polished, tapered cemented stem after total hip arthroplasty or hemiarthroplasty. METHODS: This study included 38 PPF cases after hip arthroplasty treated with revision using the Exeter stem at five institutions between 2003 and 2024. The mean age at revision surgery was 70.1 years, and the mean follow-up was 56 months. According to the Vancouver classification, fractures were classified as type AL (n = 1), type B1 (n = 10), type B2 (n = 16), and type B3 (n = 11). The re-revision rate, mortality, and functional and radiographic outcomes were assessed. RESULTS: Re-revision surgery was performed in three patients (7.9%). The cumulative survival rate, with stem re-revision as the endpoint, was 97.4% at 1 year and 93.1% at 10 years postoperatively. No deaths occurred within 1 year after revision surgery; cumulative survival, with death as the endpoint, was 100% at 1 year, 92.9% at 5 years, and 83.6% at 10 years. At the final examination, 13 cases (34.2%) were able to walk independently, and three (7.9%) used a wheelchair. Radiographic evaluation revealed radiolucency around the stem in five cases. CONCLUSIONS: Revision surgery using the Exeter stem for PPF demonstrated favorable outcomes, with low re-revision rates and mortality. This technique may be preferable for PPF because a single system accommodates multiple PPF types and is well-suited to the impaction bone grafting procedure for bone defects.

Schlagwörter

Stichwörter der Autor:innen

Exeter stemPeriprosthetic fracturePolished taper cemented stemRevision

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Shimane University, 89-1, Enya-cho, Izumo, Shimane 693-8501, Japan.
  • Center for Hip Arthroplasty, Senshunkai Hospital, 2-14-26, Kaiden, Nagaokakyo-shi 617-0826, Kyoto, Japan. Electronic address: hfshoot@gmail.com.
  • Department of Orthopaedic Surgery, Hamamatsu Medical Center, 328 Tomitsuka-cho, Chuo-ku, Hamamatsu City 432-8580, Shizuoka, Japan.
  • Department of Orthopaedic Surgery, Hokkaido Orthopaedic Memorial Hospital, 13-5-22, Hiragishi 7jo, Toyohira-ku Sapporo 062-0937, Hokkaido, Japan.
  • Department of Orthopaedic Surgery, Yamagata Saisei Hospital, 79-1, Oki-machi, Yamagata City 990-8545, Yamagata, Japan.
  • Department of Orthopaedic Surgery, Aichi Medical University, 1-1, Yazakokarimata, Nagakute-shi 480-1195, Aichi, Japan.

Zitieren

APA

Kadowaki, M., Fujita, H., Iwase, T., Oura, H., Sasaki, K., Morishima, T., Sakurai, T., Takada, R., & Uchio, Y. (2026). Multicenter retrospective study on the efficacy of reconstruction using a polished taper cemented stem for periprosthetic femoral fractures following total hip arthroplasty and hemiarthroplasty. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2026.10.009

Vancouver

Kadowaki M, Fujita H, Iwase T, Oura H, Sasaki K, Morishima T, et al. Multicenter retrospective study on the efficacy of reconstruction using a polished taper cemented stem for periprosthetic femoral fractures following total hip arthroplasty and hemiarthroplasty. Journal of Orthopaedic Science. 2026. doi:10.1016/j.jos.2026.10.009

BibTeX
@article{Kadowaki2026,
  author = {Kadowaki, Masaru and Fujita, Hiroshi and Iwase, Toshiki and Oura, Hisanori and Sasaki, Kan and Morishima, Takkan and Sakurai, Tatsuro and Takada, Ryohei and Uchio, Yuji},
  title = {Multicenter retrospective study on the efficacy of reconstruction using a polished taper cemented stem for periprosthetic femoral fractures following total hip arthroplasty and hemiarthroplasty},
  journal = {Journal of Orthopaedic Science},
  year = {2026},
  doi = {10.1016/j.jos.2026.10.009}
}
Kostenlos starten →