Percutaneous treatment of type C distal radius fractures using dual-external fixator
Journal of Orthopaedic Science · 2025
DOI: 10.1016/j.jos.2024.07.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Science, 2025. Verfasst von Xiaofei Yu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: yuxiaofei66@126.com. Hauptthemen laut MEDLINE: Radius Fractures, External Fixators, Fracture Fixation. Die Arbeit nennt 33 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: This study aimed to introduce a potential alternative percutaneous treatment for AO types C1, C2, and C3 distal radius fractures using dual-external fixator (a no-bridging cemented-pin frame and a conventional wrist-bridging external fixator). MATERIALS AND METHODS: From January 2018 to January 2021, 52 patients (52 distal radius fractures) were treated with dual-external fixator. For comparison, 61 patients (61 distal radius fractures) were treated with a plate and screw system. Wrist function was assessed using the Mayo Wrist Score. Patient satisfaction was assessed using the Short Assessment of Patient Satisfaction. A P 0.05), the patients treated with dual-external fixator and a plate and screw system achieved mean ulnar deviations of 31° vs 29° (P 0.05). CONCLUSIONS: AO types C1, C2, and C3 distal radius fractures can be treated successfully using dual-external fixator. The technique is a potential alternative in addition to the conventional treatments. LEVEL OF EVIDENCE: Level IIa.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: yuxiaofei66@126.com.
- Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: ahand@sina.com.
- Department of Neuromuscular Diseases, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 273960661@qq.com.
- Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 13313010289@163.com.
- Department of Hand Surgery, Third Hospital of Heibei Medical University, Shijiazhuang, Hebei, 050051, China. Electronic address: 13930156286@163.com.
Zitieren
APA
Yu, X., Zhang, X., Li, N., Yu, Y., & Yang, X. (2025). Percutaneous treatment of type C distal radius fractures using dual-external fixator. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2024.07.004
Vancouver
Yu X, Zhang X, Li N, Yu Y, Yang X. Percutaneous treatment of type C distal radius fractures using dual-external fixator. Journal of Orthopaedic Science. 2025. doi:10.1016/j.jos.2024.07.004
BibTeX
@article{Yu2025,
author = {Yu, Xiaofei and Zhang, Xu and Li, Nan and Yu, Yadong and Yang, Xiaoliang},
title = {Percutaneous treatment of type C distal radius fractures using dual-external fixator},
journal = {Journal of Orthopaedic Science},
year = {2025},
doi = {10.1016/j.jos.2024.07.004}
}