Analysis of accuracy of pedicle screw placement in dysplastic pedicles in adolescent idiopathic scoliosis using the pedicle expansion technique with CT-based navigation
Journal of Orthopaedic Science · 2024
DOI: 10.1016/j.jos.2023.03.019 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Science, 2024. Verfasst von Masashi Miyazaki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan. Electronic address: masashim@oita-u.ac.jp. Hauptthemen laut MEDLINE: Scoliosis, Pedicle Screws, Tomography, X-Ray Computed, Spinal Fusion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: This study aimed to study the accuracy of pedicle screw (PS) insertion into dysplastic pedicles in adolescent idiopathic scoliosis (AIS) comparing cannulated screw using the pedicle expansion technique (PET) versus conventional technique. METHODS: Forty-two AIS patients with 766 PSs were evaluated. In total, 236 screws were inserted into dysplastic pedicles: 138 and 98 screws were inserted using the PET (PET group) and standard technique (conventional group), respectively. Both methods used CT-based navigation to determine the insertion point. In the PET, a rigid ball tip feeler was tapped with a mallet to create an insertion route, a guide wire was passed through the tap, the pedicle was enlarged, and then a cannulated PS with a diameter of 4.35 mm was inserted. Postoperative CT was used to compare the accuracy of PS insertion. RESULTS: In total, 23/236 (9.7%) perforations occurred. Regarding overall perforation, there were six (4.3%) and 17 (17.3%) cases in the PET and conventional group, respectively (P = 0.008). In terms of medial perforation, the PET group (n = 2, 1.4%) was significantly better than the conventional group (n = 7, 7.1%) (P = 0.021). In terms of lateral perforation, the PET group (n = 4, 2.9%) was significantly better than conventional group (n = 10, 10.2%) (P = 0.030). Only grade 1 perforation had occurred in the PET group, whereas grades 2 and 3 perforation occurred in the conventional group. CONCLUSION: Use of the PET with CT-based navigation significantly increased the accuracy and safety of PS insertion in dysplastic pedicles in AIS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan. Electronic address: masashim@oita-u.ac.jp.
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan.
Zitieren
APA
Miyazaki, M., Abe, T., Sako, N., Kanezaki, S., & Tsumura, H. (2024). Analysis of accuracy of pedicle screw placement in dysplastic pedicles in adolescent idiopathic scoliosis using the pedicle expansion technique with CT-based navigation. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2023.03.019
Vancouver
Miyazaki M, Abe T, Sako N, Kanezaki S, Tsumura H. Analysis of accuracy of pedicle screw placement in dysplastic pedicles in adolescent idiopathic scoliosis using the pedicle expansion technique with CT-based navigation. Journal of Orthopaedic Science. 2024. doi:10.1016/j.jos.2023.03.019
BibTeX
@article{Miyazaki2024,
author = {Miyazaki, Masashi and Abe, Tetsutaro and Sako, Noriaki and Kanezaki, Shozo and Tsumura, Hiroshi},
title = {Analysis of accuracy of pedicle screw placement in dysplastic pedicles in adolescent idiopathic scoliosis using the pedicle expansion technique with CT-based navigation},
journal = {Journal of Orthopaedic Science},
year = {2024},
doi = {10.1016/j.jos.2023.03.019}
}
EUVIMED