EUVIMEDEUVIMED entdecken
Crossref

More than 10 years’ follow-up of the Swanson metacarpophalangeal joint arthroplasty for the rheumatoid hand

Kei Funamura, Hajime Ishikawa, Asami Abe, Satoshi Ito, Hiroshi Otani, Sayuri Takamura, Masanori Sudo, Kiyoshi Nakazono, Akira Murasawa

Journal of Orthopaedic Science · 2024

DOI: 10.1016/j.jos.2023.03.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Science, 2024. Verfasst von Kei Funamura und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rheumatology, Niigata Rheumatic Center, 1-2-8 Shibata City, Niigata 957-0054, Japan. Hauptthemen laut MEDLINE: Metacarpophalangeal Joint, Arthritis, Rheumatoid, Joint Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In recent years, advances in pharmacotherapy for rheumatoid arthritis have dramatically improved the control of disease activity. However, a significant number of patients still develop hand deformity and require surgical reconstruction. The objective of this study was to evaluate the long-term efficacy and drawbacks of the Swanson metacarpophalangeal joint arthroplasty for patients with rheumatoid arthritis over 10 years. METHODS: Clinical and radiological evaluations were performed for 87 joints of 29 hands in 27 patients who underwent metacarpophalangeal joint arthroplasty using the Swanson implant, and who were followed up for an average of 11.4 (10-14) years. RESULTS: The number of operated tender and swollen metacarpophalangeal joints decreased from 24 (27.6%) and 28 (32.2%) to 1 (1.1%) and 2 (2.3%), respectively. The patients' general health and disease activity score 28-erythrocyte sedimentation rate improved at the last survey. Mild recurrence of ulnar drift was observed, but the deformity was generally well-corrected. Implant fracture was noted in eight joints (9.2%), and revision surgery was performed in two joints (2.3%). The average active range of extension/flexion changed from -46.3°/65.9° to -32.3°/56.6°. While a significant change was not noted in grip or pinch strength, patients were satisfied with the operation especially in terms of pain relief and improved hand appearance. CONCLUSIONS: The long-term results of Swanson metacarpophalangeal joint arthroplasty were good in pain relief and correction of deformity, but some problems remain with regard to implant durability and mobility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metacarpophalangeal JointArthritis, RheumatoidJoint ProsthesisHumansMaleFemaleMiddle AgedFollow-Up StudiesAgedAdultRange of Motion, ArticularTime FactorsTreatment OutcomeRetrospective StudiesProsthesis DesignArthroplasty, Replacement, FingerArthroplasty, Replacement

Stichwörter der Autor:innen

ArthroplastyHandMetacarpophalangeal jointRheumatoid arthritisSurgerySwanson implant

Autor:innen und Institutionen

  • Department of Rheumatology, Niigata Rheumatic Center, 1-2-8 Shibata City, Niigata 957-0054, Japan.
  • Department of Rheumatology, Niigata Rheumatic Center, 1-2-8 Shibata City, Niigata 957-0054, Japan. Electronic address: med@ra-center.com.

Zitieren

APA

Funamura, K., Ishikawa, H., Abe, A., Ito, S., Otani, H., Takamura, S., Sudo, M., Nakazono, K., & Murasawa, A. (2024). More than 10 years’ follow-up of the Swanson metacarpophalangeal joint arthroplasty for the rheumatoid hand. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2023.03.013

Vancouver

Funamura K, Ishikawa H, Abe A, Ito S, Otani H, Takamura S, et al. More than 10 years’ follow-up of the Swanson metacarpophalangeal joint arthroplasty for the rheumatoid hand. Journal of Orthopaedic Science. 2024. doi:10.1016/j.jos.2023.03.013

BibTeX
@article{Funamura2024,
  author = {Funamura, Kei and Ishikawa, Hajime and Abe, Asami and Ito, Satoshi and Otani, Hiroshi and Takamura, Sayuri and Sudo, Masanori and Nakazono, Kiyoshi and Murasawa, Akira},
  title = {More than 10 years’ follow-up of the Swanson metacarpophalangeal joint arthroplasty for the rheumatoid hand},
  journal = {Journal of Orthopaedic Science},
  year = {2024},
  doi = {10.1016/j.jos.2023.03.013}
}
Kostenlos starten →