Variability in sonographic anterior drawer test measurements of the ankle: Experienced versus beginner examiners

Shuhei Iwata, Satoshi Yamaguchi, Seiji Kimura, Soichi Hattori, Yukio Mikami, Yohei Kawasaki, Yuki Shiko, Ryuichiro Akagi, Kentaro Amaha, Tomonori Atsuta, Naoshi Ikegawa, Minoru Koyama und 8 weitere

Journal of Orthopaedic Science · 2024

DOI: 10.1016/j.jos.2022.12.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Science, 2024. Verfasst von Shuhei Iwata und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan. Hauptthemen laut MEDLINE: Ankle Injuries, Joint Instability, Lateral Ligament, Ankle. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study aimed to clarify the variability in the measurements of stress sonography of the ankle and determine the effects of examiner experience on the measurements. METHODS: Twenty examiners (10 experienced and 10 beginners) were included in the study. Each examiner performed stress ultrasonography on a patient with a chronic anterior talofibular ligament injury and a patient with an intact ligament using the reverse anterior drawer method. Changes in ligament length before versus after stress were determined. The same 20 examiners performed ultrasonography on two other patients with an injured or intact ATFL using the anterior drawer method. The length change values and variance were compared between the groups using t-tests and F-tests. RESULTS: Using the reverse anterior drawer method, the change in the anterior talofibular ligament length was 3.3 mm (range, 2.2-4.8 mm) in the experienced group and 2.7 mm (0.0-4.1 mm) in the beginner group for the ligament injured patient. The length changes for the patient with intact anterior talofibular ligament were 0.5 mm (0.1-0.9 mm) and 0.4 mm (-0.1-1.5 mm) in the experienced and beginner groups, respectively. There were no significant intergroup differences in measurement amount (P = 0.37) or variance (P = 0.72). Similarly, using the anterior drawer method, no significant differences between the groups were found in measurement amount or variance. CONCLUSION: The quantitative evaluation of stress sonography of the ankle was variable regardless of examiner experience or stress method, particularly in patients with an anterior talofibular ligament injury. The amount of variability appeared to be unacceptably large for clinical application. Our study results highlight the need for technical standardization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ankle InjuriesJoint InstabilityLateral Ligament, AnkleHumansAnkleAnkle JointUltrasonography

Stichwörter der Autor:innen

Ankle instabilityAnterior drawer testAnterior talofibular ligamentStress ultrasonographyUltrasonography

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan.
  • Department of Orthopaedic Surgery, Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan; Graduate School of Global and Transdisciplinary Studies, Chiba University, Chiba, Japan. Electro…
  • Biostatistics Section, Clinical Research Center, Chiba University Hospital, Chiba, Japan.
  • Department of Orthopaedic Surgery, Oyumino Central Hospital, Chiba, Japan.
  • Department of Orthopaedic Surgery, St. Luke's International Hospital, Tokyo, Japan.
  • Atsuta Orthopaedic Clinic, Chiba, Japan.

Zitieren

APA

Iwata, S., Yamaguchi, S., Kimura, S., Hattori, S., Mikami, Y., Kawasaki, Y., Shiko, Y., Akagi, R., Amaha, K., Atsuta, T., Ikegawa, N., Koyama, M., Nakagawa, R., Omodani, T., Ouchi, H., Saito, M., Takahashi, K., Watanabe, S., Sasho, T., & Ohtori, S. (2024). Variability in sonographic anterior drawer test measurements of the ankle: Experienced versus beginner examiners. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2022.12.005

Vancouver

Iwata S, Yamaguchi S, Kimura S, Hattori S, Mikami Y, Kawasaki Y, et al. Variability in sonographic anterior drawer test measurements of the ankle: Experienced versus beginner examiners. Journal of Orthopaedic Science. 2024. doi:10.1016/j.jos.2022.12.005

BibTeX
@article{Iwata2024,
  author = {Iwata, Shuhei and Yamaguchi, Satoshi and Kimura, Seiji and Hattori, Soichi and Mikami, Yukio and Kawasaki, Yohei and Shiko, Yuki and Akagi, Ryuichiro and Amaha, Kentaro and Atsuta, Tomonori and Ikegawa, Naoshi and Koyama, Minoru and Nakagawa, Ryosuke and Omodani, Toru and Ouchi, Hiroshi and Saito, Masahiko and Takahashi, Kenji and Watanabe, Shotaro and Sasho, Takahisa and Ohtori, Seiji},
  title = {Variability in sonographic anterior drawer test measurements of the ankle: Experienced versus beginner examiners},
  journal = {Journal of Orthopaedic Science},
  year = {2024},
  doi = {10.1016/j.jos.2022.12.005}
}
Kostenlos starten →