Imageless kinematic versus CT-based functional alignment in robotic-assisted total knee arthroplasty: A propensity score–matched comparative study
Journal of Orthopaedics · 2026-07 · 77 · 29-35
DOI: 10.1016/j.jor.2026.04.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedics, 2026-07. Verfasst von Yong Ng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Singapore General Hospital, Singapore Health Services, 1 Hospital Boulevard, Singapore, 168581, Singapore. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Aims and objectives: Robotic-assisted total knee arthroplasty (rTKA) enables reproducible implementation of personalized alignment strategies, including kinematic alignment (KA) and functional alignment (FA). However, direct comparative data between imageless KA-rTKA and CT-based FA-rTKA remain limited. This study compared six-month patient-reported outcome measures (PROMs) between these strategies, with early postoperative recovery evaluated as secondary outcomes. Materials and methods: A retrospective analysis of 206 propensity-matched primary rTKA cases (January 2024-January 2025) was conducted. Matching was based on age, sex, body mass index, and baseline PROMs. Primary outcomes included six-month Knee Society Scores (KSS), Oxford Knee Score (OKS), Short Form-36 (SF-36), minimal clinically important difference (MCID) achievement, patient satisfaction, and expectation fulfillment. Secondary outcomes included postoperative day one (POD1) knee range of motion, pain scores, and ambulation distance.
Results
The matched cohort comprised 128 females and 78 males, with mean age 68.7 ± 7.7 years and body mass index 27.1 ± 4.8 kg/m2. Six-month PROMs, MCID achievement, satisfaction, and expectation fulfillment were comparable between groups (all P > 0.05). The KA-rTKA group demonstrated greater POD1 ambulation distance compared with FA-rTKA (22.6 ± 21.1 m vs 15.8 ± 12.2 m; P = 0.010), with no significant differences in pain scores or knee range of motion.
Conclusion
Imageless KA-rTKA and CT-based FA-rTKA produced equivalent six-month functional outcomes. While KA-rTKA demonstrated modestly greater early ambulation, this did not translate into clinically meaningful differences at six months, suggesting both alignment strategies achieve similar short-term outcomes with robotic assistance. Level of evidence: III, retrospective comparative cohort study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Singapore General Hospital, Singapore Health Services, 1 Hospital Boulevard, Singapore, 168581, Singapore.
- Duke-NUS Medical School, 8 College Road, Singapore, 169857, Singapore.
- Department of Orthopaedics, Traumatology and Rehabilitation, International Islamic University Malaysia, Jalan Sultan Ahmad Shah, 25200, Kuantan, Pahang, Malaysia.
Zitieren
APA
Ng, Y., Lim, J. T. E., Kow, R. Y., Pang, H. N., Tay, D. K. J., Yeo, S. J., & Liow, M. H. L. (2026). Imageless kinematic versus CT-based functional alignment in robotic-assisted total knee arthroplasty: A propensity score–matched comparative study. Journal of Orthopaedics, 77, 29-35. https://doi.org/10.1016/j.jor.2026.04.015
Vancouver
Ng Y, Lim JTE, Kow RY, Pang HN, Tay DKJ, Yeo SJ, et al. Imageless kinematic versus CT-based functional alignment in robotic-assisted total knee arthroplasty: A propensity score–matched comparative study. Journal of Orthopaedics. 2026;77:29-35. doi:10.1016/j.jor.2026.04.015
BibTeX
@article{Ng2026,
author = {Ng, Yong and Lim, Jeremy Tze En and Kow, Ren Yi and Pang, Hee Nee and Tay, Darren Keng Jin and Yeo, Seng Jin and Liow, Ming Han Lincoln},
title = {Imageless kinematic versus CT-based functional alignment in robotic-assisted total knee arthroplasty: A propensity score–matched comparative study},
journal = {Journal of Orthopaedics},
year = {2026},
volume = {77},
pages = {29--35},
doi = {10.1016/j.jor.2026.04.015}
}
EUVIMED