Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review
Journal of Orthopaedics · 2026-04 · 74 · 404-411
DOI: 10.1016/j.jor.2026.02.017 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Orthopaedics, 2026-04. Verfasst von Hassaan Abdel Khalik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedics, Department of Surgery, McMaster University, Hamilton, Ontario, Canada. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Patients with moderate-to-severe varus or valgus deformities present with unique considerations. Therefore, this systematic review aims to evaluate the effectiveness of robotic-assisted total knee arthroplasty (RA-TKA) in addressing moderate-to-severe coronal plane deformities.
Methods
MEDLINE, Embase, and Web of Science were searched from inception to January 4, 2025, for single-arm or comparative studies assessing the efficacy of robotic-assisted total knee arthroplasty (RA-TKA) in patients with moderate-to-severe coronal plane deformities undergoing primary surgery. Primary outcome included patient-reported outcomes (PROs), radiographic outcomes, operative times, and complication rates.
Results
Eight studies (1274 knees) were included in this study. Of 1244 knees (97.6%) replaced with RA-TKA, 599 presented with pre-operative varus deformity group (47.0%), 82 with valgus deformity group (6.4%), and 563 with minimal to no preoperative deformity (44.2%) used as a control. The remaining 30 patients were in a conventional technique (C-TKA) control group (2.4%). PROs at 1-year postoperatively and beyond were comparable across both varus and valgus knees, and their respective comparator groups. Only one study reported a significant difference in radiographic outlier between RA-TKA and C-TKA, in favor of the former. Operative times were conflicting when comparing RA-TKA versus C-TKA. Limited studies demonstrated no difference in complication rates.
Conclusion
RA-TKA reliably attains target radiographic alignment with favorable patient reported outcomes. Several methodological concerns have been highlighted to aid in the development of future studies including the standardization of moderate-to-severe deformity, reporting on associated soft-tissue releases as well as minimization of heterogenous implant use within studies. Loe: IV.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Orthopaedics, Department of Surgery, McMaster University, Hamilton, Ontario, Canada.
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
Zitieren
APA
Abdel Khalik, H., Aldawodi, M., Lameire, D. L., Wood, T. J., Khanna, V., & Adili, A. (2026). Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review. Journal of Orthopaedics, 74, 404-411. https://doi.org/10.1016/j.jor.2026.02.017
Vancouver
Abdel Khalik H, Aldawodi M, Lameire DL, Wood TJ, Khanna V, Adili A. Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review. Journal of Orthopaedics. 2026;74:404-411. doi:10.1016/j.jor.2026.02.017
BibTeX
@article{AbdelKhalik2026,
author = {Abdel Khalik, Hassaan and Aldawodi, Mohamed and Lameire, Darius L and Wood, Thomas J and Khanna, Vickas and Adili, Anthony},
title = {Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review},
journal = {Journal of Orthopaedics},
year = {2026},
volume = {74},
pages = {404--411},
doi = {10.1016/j.jor.2026.02.017}
}
EUVIMED