EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling

Mohammadjavad Matin Einafshar, Mohadese Rajaeirad, Ahmad Babazadeh Ghazijahani, Michael Skipper Andersen

Journal of Orthopaedics · 2024-10 · 56 · 70-76

DOI: 10.1016/j.jor.2024.05.016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedics, 2024-10. Verfasst von Mohammadjavad Matin Einafshar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Material and Production, Aalborg University, Aalborg, Denmark. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cortical bone drilling is integral to orthopedic and dental surgeries, yet challenges such as thermal necrosis persist. Previous finite element (FE) models may overlook critical parameters, impacting accuracy. This study aims to integrate experimental and computational approaches to predict essential parameters-initial temperature, point angle, and spindle speed-enhancing precision in cortical bone drilling.

Methods

Bovine cortical samples were utilized to systematically investigate the impact of four independent parameters on maximum temperature (MT) and maximum thrust force (MTF). Parameters included drill bit initial temperature (IT), diameter, point angle, and spindle speed (225-2700 rpm, feed rate 0.5-3 mm/s). Experimental procedures involved an orthopedic handpiece with titanium drill bits. DEFORM-3D V6.02 facilitated FE simulation, with the validated model developed for the second stage of the drilling process.

Results

The validated model highlighted the significant impact of drill bit IT on MT, predicting a 26.14 % decrease in final bone temperature as IT decreased from 25 to 5 °C. Increasing the point angle from 70 to 120° resulted in a 13.1 % MT increase and a 26.9 % decrease in MTF. Spindle speed variations exhibited a 48.3 % temperature increase and an 82.8 % MTF decrease.

Conclusions

Integrating experimental validation and computational modeling offers a comprehensive approach to predict drilling parameters. Precision in cortical bone drilling can be optimized by selecting specific parameters, including lower drill bit IT, smaller point angles, and controlled spindle speeds. This optimization reduces the risk of bone necrosis and thermal damage, thereby enhancing surgical outcomes.

Schlagwörter

Stichwörter der Autor:innen

Controlled bone drillingCortical bone drilling kinematicsDrill bit designExcessive heatFinite element prediction

Autor:innen und Institutionen

  • Department of Material and Production, Aalborg University, Aalborg, Denmark.
  • Department of Biomedical Engineering, University of Isfahan, Isfahan, Iran.
  • Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.

Zitieren

APA

Einafshar, M. M., Rajaeirad, M., Babazadeh Ghazijahani, A., & Skipper Andersen, M. (2024). On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling. Journal of Orthopaedics, 56, 70-76. https://doi.org/10.1016/j.jor.2024.05.016

Vancouver

Einafshar MM, Rajaeirad M, Babazadeh Ghazijahani A, Skipper Andersen M. On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling. Journal of Orthopaedics. 2024;56:70-76. doi:10.1016/j.jor.2024.05.016

BibTeX
@article{Einafshar2024,
  author = {Einafshar, Mohammadjavad Matin and Rajaeirad, Mohadese and Babazadeh Ghazijahani, Ahmad and Skipper Andersen, Michael},
  title = {On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling},
  journal = {Journal of Orthopaedics},
  year = {2024},
  volume = {56},
  pages = {70--76},
  doi = {10.1016/j.jor.2024.05.016}
}
Kostenlos starten →