Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study
Journal of Endodontics · 2025
DOI: 10.1016/j.joen.2025.09.003 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Endodontics, 2025. Verfasst von Celso Luiz Caldeira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, São Paulo, Brazil. Electronic address: celcalde@usp.br. Hauptthemen laut MEDLINE: Oximetry, Smartphone, Dental Pulp, Pulpitis. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Pulse oximetry exhibits great potential for use in endodontic diagnosis as an effective method to assess pulp vitality. Cell phone-integrated oximeters represent an emerging alternative that may offer greater accessibility. This study aimed to investigate the relation between pulp oxygenation rates (%SpO2) and clinical diagnosis of healthy pulp (HP), reversible pulpitis (RP), symptomatic irreversible pulpitis (IP), or pulp necrosis (PN), comparing 2 pulse oximeters (conventional [PO1] and mobile-connected). METHODS: Thirty affected premolars were grouped according to the clinical diagnosis of RP, IP, or PN and compared to vitality diagnosis by %SpO2 obtained by both pulse oximeters: PO1 and by smartphone-based (PO2). For each affected tooth, 2 additional teeth (adjacent and contralateral) with HP were tested. Statistical analysis was performed using one-way ANOVA with Tukey's post-hoc test. RESULTS: The mean %SpO2 values measured by PO1 were 87.7% for RP, 80.5% for IP, 73.2% for PN, and 91.89% for HP. Corresponding values obtained with PO2 were 85.6% (RP), 79.3% (IP), 72.1% (PN), and 90.1% (HP). Significant differences in %SpO2 were observed among RP, IP, and PN groups (P < .05), but not between healthy control subgroups (adjacent and contralateral). PO1 consistently recorded higher oxygen saturation than PO2 across all clinical conditions (P < .05), demonstrating superior discriminatory capability. CONCLUSIONS: Both pulse oximeters demonstrated significant clinical value for pulp vitality assessment and differentiation of pulpal inflammation stages and necrosis. The smartphone-adapted oximeter has proven to be comparable to PO1 in diagnostic performance, while offering data collection efficiency and clinical workflow integration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, São Paulo, Brazil. Electronic address: celcalde@usp.br.
- Department of Endodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, São Paulo, Brazil.
- Department of Endodontics, School of Dentistry, Lutheran University of Brazil, Canoas, Rio Grande do Sul, Brazil.
- Department of Periodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, São Paulo, Brazil.
Zitieren
APA
Caldeira, C. L., Diaz Zamalloa, S. I., Guimaro Sakitani, C. R., Barletta, F. B., & Holzhausen, M. (2025). Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study. Journal of Endodontics. https://doi.org/10.1016/j.joen.2025.09.003
Vancouver
Caldeira CL, Diaz Zamalloa SI, Guimaro Sakitani CR, Barletta FB, Holzhausen M. Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study. Journal of Endodontics. 2025. doi:10.1016/j.joen.2025.09.003
BibTeX
@article{Caldeira2025,
author = {Caldeira, Celso Luiz and Diaz Zamalloa, Stephanie Isabel and Guimaro Sakitani, Claudia Regina and Barletta, Fernando Branco and Holzhausen, Marinella},
title = {Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study},
journal = {Journal of Endodontics},
year = {2025},
doi = {10.1016/j.joen.2025.09.003}
}
EUVIMED