Cyclic Fatigue Evaluation of Nickel-Titanium Rotary Instruments Using an Electrical Resistance-based Method
Journal of Endodontics · 2025-10 · 51 (10) · 1471-1476
DOI: 10.1016/j.joen.2025.06.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Endodontics, 2025-10. Verfasst von Congyu Yang und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Lab…. Hauptthemen laut MEDLINE: Titanium, Nickel, Root Canal Preparation, Dental Alloys. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Natural Science Foundation of Hubei Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
INTRODUCTION: This in vitro study aimed to establish the correlation between electrical resistance and cyclic fatigue of endodontic nickel-titanium (NiTi) rotary instruments as a quantifiable cyclic fatigue indicator. METHODS: Two kinds of geometrically identical NiTi rotary instruments ProTaper Universal F2 and ProTaper Gold F2 were selected and allocated into 2 experimental groups: a cyclic fatigue test group and a sterilization test group. In the cyclic fatigue test group, instruments were rotated in an artificial root canal until fracture, with the number of cycles (rotations) to fracture (NCF) recorded. In the sterilization test group, instruments were rotated to 20%, 40%, 60%, and 80% of the NCF, followed by autoclaving sterilization. Electrical resistance was measured after each 10 rotations, as well as pre- and post-sterilization. Scanning electron microscopy was applied to analyze the instrument surfaces, focusing on the expanding of microcracks over rotations and the effect of autoclaving. The collected data were then statistically analyzed. RESULTS: The results indicated that the electrical resistance of tested instruments increased quadratically with the cyclic fatigue degrees along with the expanding of microcracks. At the 80% NCF, the electrical resistance increased by 2.38% and 2.63% for PTU F2 and PTG F2 respectively. Autoclaving had no significant effect on electrical resistance. CONCLUSION: Electrical resistance could be used as a quantifiable indicator to evaluate and predict the cyclic fatigue degree of NiTi rotary instruments and seems unaffected by autoclaving.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan Univer…
Förderung
- Natural Science Foundation of Hubei Province
- National Natural Science Foundation of China
Zitieren
APA
Yang, C., Min, Y., & Fan, W. (2025). Cyclic Fatigue Evaluation of Nickel-Titanium Rotary Instruments Using an Electrical Resistance-based Method. Journal of Endodontics, 51(10), 1471-1476. https://doi.org/10.1016/j.joen.2025.06.015
Vancouver
Yang C, Min Y, Fan W. Cyclic Fatigue Evaluation of Nickel-Titanium Rotary Instruments Using an Electrical Resistance-based Method. Journal of Endodontics. 2025;51(10):1471-1476. doi:10.1016/j.joen.2025.06.015
BibTeX
@article{Yang2025,
author = {Yang, Congyu and Min, Yi and Fan, Wei},
title = {Cyclic Fatigue Evaluation of Nickel-Titanium Rotary Instruments Using an Electrical Resistance-based Method},
journal = {Journal of Endodontics},
year = {2025},
volume = {51},
number = {10},
pages = {1471--1476},
doi = {10.1016/j.joen.2025.06.015}
}
EUVIMED