EUVIMEDEUVIMED entdecken
Crossref

Effects of Additional Vertical Movements on the Torque, Force, and Root Canal Shaping Performance of Nickel-Titanium Rotary Instruments in Optimal Torque Reverse Motion

Shunsuke Kimura, Arata Ebihara, Keiichiro Maki, Moe-Sandar Kyaw, Satoshi Omori, Takashi Okiji

Journal of Endodontics · 2025

DOI: 10.1016/j.joen.2025.04.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endodontics, 2025. Verfasst von Shunsuke Kimura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science To…. Hauptthemen laut MEDLINE: Nickel, Titanium, Root Canal Preparation, Dental Instruments. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Optimal manipulation techniques for nickel-titanium rotary instrumentation using optimum torque reverse (OTR) motion, a torque-sensitive reciprocating motion, remain underexplored. This study evaluated the effects of applying "forced in-and-out motion" (i.e., downward followed by immediate upward movement upon OTR activation) on the performance of ProTaper NEXT instrumentation. METHODS: An automated instrumentation with torque/force sensing was conducted in 35 J-shaped resin canals with ProTaper Next X1 to X3, employing periodic up-and-down movements. The applied motions were; continuous rotation (group CR); OTR motion without forced in-and-out motion (group OTR-N); and OTR motion with forced in-and-out motion, featuring downward movements lasting 0.25 s, 1.0 s, and 2.0 s (groups OTR-0.25s, OTR-1s, and OTR-2s). Maximum torque/force values, instrumentation time, and canal-centering ratios were evaluated. Statistical analysis was conducted adopting two-way analysis of variance followed by a simple main effect test or Tukey test (α = 0.05). RESULTS: Groups OTR-0.25s and OTR-1s typically demonstrated significantly smaller clockwise torque, and groups CR, OTR-0.25s, and OTR-1s generally exhibited significantly smaller downward force, relative to the other groups (P < .05). Groups CR and OTR-0.25s demonstrated significantly higher canal-centering ratios (more deviations) at apical 0 mm and 0.5 mm than the other groups (P < .05). Group OTR-0.25s had the longest instrumentation time (P < .05). CONCLUSIONS: When adopting OTR motion in ProTaper Next rotary instrumentation, incorporating forced in-and-out motion with 1.0 s of downward movement reduced force/torque generation and canal-centering ratios without extending instrumentation time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NickelTitaniumRoot Canal PreparationDental InstrumentsDental AlloysTorqueHumansRotationEquipment DesignMaterials TestingMotionDental Pulp Cavity

Stichwörter der Autor:innen

Canal centering ratioforced in-and-out motionnickel–titanium rotary instrumentationoptimum torque reverse motiontorquevertical force

Substanzen

NickelTitaniumtitanium nickelideDental Alloys

Autor:innen und Institutionen

  • Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan. Electronic address: s.kimura.endo@tmd.ac…
  • Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan.
  • Tohoku University Graduate School of Dentistry Division of Operative Dentistry, Department of Ecological Dentistry, Sendai, Miyagi, Japan.
  • Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Bunkyo-ku, Tokyo, Japan; Department of Endodontics, The Nippon De…

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Kimura, S., Ebihara, A., Maki, K., Kyaw, M. S., Omori, S., & Okiji, T. (2025). Effects of Additional Vertical Movements on the Torque, Force, and Root Canal Shaping Performance of Nickel-Titanium Rotary Instruments in Optimal Torque Reverse Motion. Journal of Endodontics. https://doi.org/10.1016/j.joen.2025.04.014

Vancouver

Kimura S, Ebihara A, Maki K, Kyaw MS, Omori S, Okiji T. Effects of Additional Vertical Movements on the Torque, Force, and Root Canal Shaping Performance of Nickel-Titanium Rotary Instruments in Optimal Torque Reverse Motion. Journal of Endodontics. 2025. doi:10.1016/j.joen.2025.04.014

BibTeX
@article{Kimura2025,
  author = {Kimura, Shunsuke and Ebihara, Arata and Maki, Keiichiro and Kyaw, Moe-Sandar and Omori, Satoshi and Okiji, Takashi},
  title = {Effects of Additional Vertical Movements on the Torque, Force, and Root Canal Shaping Performance of Nickel-Titanium Rotary Instruments in Optimal Torque Reverse Motion},
  journal = {Journal of Endodontics},
  year = {2025},
  doi = {10.1016/j.joen.2025.04.014}
}
Kostenlos starten →