EUVIMEDEUVIMED entdecken
Crossref

Influence of the Brushing Motions on the Dynamic Cyclic Fatigue Resistance of the Reciproc Blue Instrument: In vitro Study

Juliana Borsoi Chicon, Vanessa Maria Fernandes Pavão, Maíra Henrique Gonçalves Cunha, Marcos Frozoni

Journal of Endodontics · 2024

DOI: 10.1016/j.joen.2024.06.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endodontics, 2024. Verfasst von Juliana Borsoi Chicon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontic, São Leopoldo Mandic School of Dentistry, Campinas, SãP Paulo, Brazil. Electronic address: juliana.borsoi@yahoo.com.br. Hauptthemen laut MEDLINE: Root Canal Preparation, Equipment Failure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study aimed to evaluate the dynamic cyclic fatigue resistance of Reciproc Blue files subjected to brushing motion. METHODS: Twenty Reciproc Blue files (R25, VDW, Munich, Germany) were employed for chemical-mechanical preparation in root canals of 3D printed replicas of mandibular molars. The instruments were divided into two groups (n = 10): Group brushing motion, instrumentation with brushing motions; Group without brushing motion , instrumentation without brushing motions. Subsequently, the same instruments underwent cyclic fatigue testing using artificial canals consisting of a stainless-steel plate and an apical segment with a 45° curvature. Data regarding the time to fracture, number of cycles to fracture, and length of the fractured fragment were collected and subjected to statistical analysis using the t-test or Mann-Whitney test, with a significance level of 5%. Additionally, the fractured fragments were examined under a scanning electron microscope. RESULTS: No statistical differences were observed between the groups in terms of time to fracture (P < .05), number of cycles to fracture (P < .05) and length of the fractured fragment (P < .05). CONCLUSION: The brushing motion did not affect the dynamic cyclic fatigue resistance of Reciproc Blue files.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal PreparationEquipment FailureHumansIn Vitro TechniquesDental InstrumentsMaterials TestingMotionToothbrushingDental Stress AnalysisEquipment DesignStress, MechanicalMolar

Stichwörter der Autor:innen

Cyclic fatigueinstrumentationreciprocating instruments

Autor:innen und Institutionen

  • Department of Endodontic, São Leopoldo Mandic School of Dentistry, Campinas, SãP Paulo, Brazil. Electronic address: juliana.borsoi@yahoo.com.br.
  • Department of Endodontic, São Leopoldo Mandic School of Dentistry, Campinas, SãP Paulo, Brazil.

Zitieren

APA

Chicon, J. B., Fernandes Pavão, V. M., Gonçalves Cunha, M. H., & Frozoni, M. (2024). Influence of the Brushing Motions on the Dynamic Cyclic Fatigue Resistance of the Reciproc Blue Instrument: In vitro Study. Journal of Endodontics. https://doi.org/10.1016/j.joen.2024.06.013

Vancouver

Chicon JB, Fernandes Pavão VM, Gonçalves Cunha MH, Frozoni M. Influence of the Brushing Motions on the Dynamic Cyclic Fatigue Resistance of the Reciproc Blue Instrument: In vitro Study. Journal of Endodontics. 2024. doi:10.1016/j.joen.2024.06.013

BibTeX
@article{Chicon2024,
  author = {Chicon, Juliana Borsoi and Fernandes Pavão, Vanessa Maria and Gonçalves Cunha, Maíra Henrique and Frozoni, Marcos},
  title = {Influence of the Brushing Motions on the Dynamic Cyclic Fatigue Resistance of the Reciproc Blue Instrument: In vitro Study},
  journal = {Journal of Endodontics},
  year = {2024},
  doi = {10.1016/j.joen.2024.06.013}
}
Kostenlos starten →