EUVIMEDEUVIMED entdecken
Vergleichsstudie

Three-Dimensional Measurement of Obturation Quality of Bioceramic Materials in Filling Artificial Internal Root Resorption Cavities Using Different Obturation Techniques: An In Vitro Comparative Study

Ammar M Sharki, Ahmed H Ali

Journal of Endodontics · 2024

DOI: 10.1016/j.joen.2024.03.014 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Endodontics, 2024. Verfasst von Ammar M Sharki und 1 weiteren Autor:innen. Beteiligte Einrichtung: Aesthetic and restorative dentistry department, College of Dentistry, University of Baghdad, Baghdad, Iraq. Hauptthemen laut MEDLINE: Root Canal Obturation, Root Canal Filling Materials, Cone-Beam Computed Tomography, Root Resorption. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Pathologic conditions such as internal root resorption (IRR) may complicate root canal filling. This study aimed to evaluate and compare the obturation quality by measuring the percentage of obturation volume (POV) in root canals with artificial IRR obturated with different materials and techniques using cone beam computed tomography (CBCT). METHODS: Forty single canal extracted mandibular premolars were decoronated to standardize their length to 14 mm. Following instrumentation, the roots were cut horizontally, and artificial IRR cavities were made at the level of 7 mm from the apex. The root halves were joined using cyanoacrylate adhesive. The samples were randomly assigned to 4 groups (n = 10), and the canals were filled as follows: single-cone technique (SC), bulk-fill Bio-C Sealer (BF), and Bio-C Repair for the coronal and middle third (BCR) + cold lateral condensation technique (CLC) for the apical third and continuous wave compaction technique (CWC). The pre- and postobturation volumes and the POV were measured in the total canal and for the apical, middle, and coronal thirds separately using CBCT and Mimics Medical software. The results were analyzed statistically using one-way ANOVA and Tukey HSD test, and statistical significance was set at P < .05. RESULTS: BF group resulted in significantly lower total, coronal, middle and apical POV values compared to SC, BCR + CLC, and CWC groups (P < .05), respectively. Also, at the apical third, the BCR + CLC group showed significantly lower POV than the SC and CWC groups (P < .05), respectively. The intra-group comparison showed that BF and BCR + CLC groups had a significantly lower POV in the apical third compared to the middle third (P < .05). Conversely, the CWC group had a significantly higher apical POV than the middle third (P < .05). CONCLUSIONS: The maximum POV was obtained using the CWC technique, Bio-C Repair, and SC technique with Bio-C Sealer, making their application in IRR more preferable than the BF Bio-C Sealer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal ObturationRoot Canal Filling MaterialsCone-Beam Computed TomographyRoot ResorptionHumansCeramicsIn Vitro TechniquesImaging, Three-DimensionalDental Pulp CavityBicuspid

Stichwörter der Autor:innen

Bio-C sealerBioceramicCone-beam computed tomographyInternal root resorptionSingle-cone technique

Substanzen

Root Canal Filling Materials

Autor:innen und Institutionen

  • Aesthetic and restorative dentistry department, College of Dentistry, University of Baghdad, Baghdad, Iraq.
  • Assistant Professor Dr., Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Baghdad, Iraq. Electronic address: ahmed.ali@codental.uobaghdad.edu.iq.

Zitieren

APA

Sharki, A. M., & Ali, A. H. (2024). Three-Dimensional Measurement of Obturation Quality of Bioceramic Materials in Filling Artificial Internal Root Resorption Cavities Using Different Obturation Techniques: An In Vitro Comparative Study. Journal of Endodontics. https://doi.org/10.1016/j.joen.2024.03.014

Vancouver

Sharki AM, Ali AH. Three-Dimensional Measurement of Obturation Quality of Bioceramic Materials in Filling Artificial Internal Root Resorption Cavities Using Different Obturation Techniques: An In Vitro Comparative Study. Journal of Endodontics. 2024. doi:10.1016/j.joen.2024.03.014

BibTeX
@article{Sharki2024,
  author = {Sharki, Ammar M and Ali, Ahmed H},
  title = {Three-Dimensional Measurement of Obturation Quality of Bioceramic Materials in Filling Artificial Internal Root Resorption Cavities Using Different Obturation Techniques: An In Vitro Comparative Study},
  journal = {Journal of Endodontics},
  year = {2024},
  doi = {10.1016/j.joen.2024.03.014}
}
Kostenlos starten →