EUVIMEDEUVIMED entdecken
Crossref

Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?

João Pedro de Lima, Jardel Francisco Mazzi-Chaves, Manoel Damião de Sousa-Neto, Amanda Pelegrin Candemil

Journal of Endodontics · 2023

DOI: 10.1016/j.joen.2023.07.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endodontics, 2023. Verfasst von João Pedro de Lima und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil. Hauptthemen laut MEDLINE: Endodontics, Endodontists. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Cone-beam computed tomography (CBCT) allows three-dimensional evaluation and has high diagnostic accuracy of endodontic conditions. Considering that the most indicated protocol for endodontics should have smaller field-of-view and higher spatial resolution, a higher radiation dose may be associated. Thus, this study evaluated the accuracy of an optimized CBCT protocol for the detection of intraoperative endodontic complications. METHODS: An image phantom was custom-made with a human mandible covered with Mix-D and forty mandibular first molars. The teeth were subdivided into 4 groups of endodontic complications which were simulated. All teeth were individually inserted into the left second molar socket of the phantom and CBCT images were acquired with OP 300 unit adjusted to a field-of-view of 6 × 4 cm, 90kVp, and 2 dose protocols: low and high. Furthermore, a titanium implant, a tooth with endodontic treatment, and a cobalt-chromium post were inserted into the empty sockets adjacent to the teeth of interest and additional images were acquired. Four endodontists evaluated the images and indicated the presence of endodontic complications on a 5-point scale. Sensitivity, specificity, and area under the receiver operating characteristic curve were obtained. The different groups were compared by ANOVA and Tukey tests (α = 0.05). RESULTS: In most conditions, irrespective of the presence of metallic materials, the values of accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve did not differ significantly (P > .05) between the dose protocols. CONCLUSIONS: Optimized CBCT protocols should be considered for the detection of intraoperative endodontic Diagnostic complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndodonticsEndodontistsHumansROC CurveCone-Beam Computed TomographyMolar

Stichwörter der Autor:innen

Cone-beam computed tomographydiagnostic imagingendodonticsradiological protection

Autor:innen und Institutionen

  • Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil.
  • Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil. Electronic address: amandacandemil@hotmail.com.

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo

Zitieren

APA

de Lima, J. P., Mazzi-Chaves, J. F., de Sousa-Neto, M. D., & Candemil, A. P. (2023). Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?. Journal of Endodontics. https://doi.org/10.1016/j.joen.2023.07.006

Vancouver

de Lima JP, Mazzi-Chaves JF, de Sousa-Neto MD, Candemil AP. Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?. Journal of Endodontics. 2023. doi:10.1016/j.joen.2023.07.006

BibTeX
@article{deLima2023,
  author = {de Lima, João Pedro and Mazzi-Chaves, Jardel Francisco and de Sousa-Neto, Manoel Damião and Candemil, Amanda Pelegrin},
  title = {Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?},
  journal = {Journal of Endodontics},
  year = {2023},
  doi = {10.1016/j.joen.2023.07.006}
}
Kostenlos starten →