Fachartikel in der Zeitschrift Journal of Clinical Densitometry, 2024. Verfasst von Grace L Rose und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Health, University of the Sunshine Coast, Sippy Downs, Australia; School of Human Movement and Nutrition Sciences, The University of Queens…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Muscle, Skeletal, Bone Density. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Reliable peripheral quantitative computed tomography (pQCT) assessment is essential to the accurate longitudinal reporting of bone and muscle quality. However, the between-day reliability of pQCT and the influence of age on outcome reliability is currently unknown. OBJECTIVE: To quantify the same- and between-day reliability of morphological pQCT at proximal and distal segments of the forearm, shank, and thigh, and explore the influence of participant body size, age, and sex on outcome reliability. METHODS: Men and women (49 % female, 18-85 years, n=72-86) completed two consecutive-day pQCT testing sessions, where repeat measurements were conducted on day-one for technical error, and between-day for biological error quantification. Testing was undertaken following best practice body composition testing guidance, including standardized presentation and consistent time-of-day. RESULTS: All measurements of bone were classified as having 'good' to 'excellent' reliability [intraclass correlation coefficient (r=0.786- 0.999], as were measurements of muscle area (ICC r=0.991-0.999) and total fat (r=0.996-0.999). However, between- and same-day muscle density measurements at the thigh and forearm were classified as 'poor' (r=0.476) and 'moderate' (r=0.622), respectively. Likewise, intramuscular fat area at the thigh was classified as 'moderate' (r=0.737) for between-day measurement. Biological error was inflated compared to technical error by an average of 0.4 % for most measurements. Error values tended to increase proportionally with the amount of tissue quantified and males had significantly greater biological error for measurement of distal tibial bone (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Health, University of the Sunshine Coast, Sippy Downs, Australia; School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Australia; Sunshine Coast Health Institute, Birtinya,…
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Australia.
- School of Health, University of the Sunshine Coast, Sippy Downs, Australia; Sunshine Coast Health Institute, Birtinya, Australia.
- School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Australia; School of Sport, Science and Rehabilitation, University of Technology Sydney, Sydney, Australia.
- School of Health, University of the Sunshine Coast, Sippy Downs, Australia.
- School of Health, University of the Sunshine Coast, Sippy Downs, Australia; School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Australia; School of Sport, Science and Rehabilitation…
Zitieren
APA
Rose, G. L., Boytar, A. N., King, I. N., Farley, M. J., Maugham-Macan, M., Skinner, T. L., Bolam, K. A., & Schaumberg, M. A. (2024). Technical and Biological Reliability of pQCT Measured Bone and Muscle Tissue Quality Across the Age-Span. Journal of Clinical Densitometry. https://doi.org/10.1016/j.jocd.2024.101522
Vancouver
Rose GL, Boytar AN, King IN, Farley MJ, Maugham-Macan M, Skinner TL, et al. Technical and Biological Reliability of pQCT Measured Bone and Muscle Tissue Quality Across the Age-Span. Journal of Clinical Densitometry. 2024. doi:10.1016/j.jocd.2024.101522
BibTeX
@article{Rose2024,
author = {Rose, Grace L and Boytar, Alex N and King, Isabel N and Farley, Morgan J and Maugham-Macan, Michelle and Skinner, Tina L and Bolam, Kate A and Schaumberg, Mia A},
title = {Technical and Biological Reliability of pQCT Measured Bone and Muscle Tissue Quality Across the Age-Span},
journal = {Journal of Clinical Densitometry},
year = {2024},
doi = {10.1016/j.jocd.2024.101522}
}
EUVIMED