Digital-like contamination in the Clock Drawing Test: Norms across six scoring systems
Journal of the Neurological Sciences · 2026-12 · 491 · 126239
DOI: 10.1016/j.jns.2026.126239 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Neurological Sciences, 2026-12. Verfasst von Ciro Rosario Ilardi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Education, Psychology and Communication, Suor Orsola Benincasa University, Naples, Italy. Hauptthemen laut MEDLINE: Neuropsychological Tests. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: In an era in which time is increasingly read from digital devices, the Clock Drawing Test (CDT) may capture not only cognitive impairment but also construct-irrelevant variance associated with reduced analog clock usage. OBJECTIVE: We aimed to derive updated normative data for CDT while modeling the impact of digital-like (DL) contamination on score interpretation. METHODS: This cross-sectional study enrolled cognitively healthy adults aged 18-94 years. Clock drawings were scored using six established methods. DL patterns were identified, including five-minute sequencing (e.g., 5-55) and post-meridiem mapping (e.g., 13-23). We then examined whether the frequency of digital timekeeping was associated with CDT performance and the probability of relying on DL strategies. Psychometric rules for score adjustment and interpretation were computed. RESULTS: The sample included 560 participants (357 women). The scoring methods showed moderate-to-strong intercorrelations (ρ = 0.45-0.79), with good-to-excellent inter-rater reliability (ICC = 0.78-0.95). DL patterns occurred in 45 individuals (8%) and were not associated with cognitive functioning. As participants' age increased, the more frequent the use of digital devices for time-checking, the poorer the CDT performance (b = -0.051, 95% CI [-0.086, -0.017]) and the greater the likelihood of producing DL patterns (b = 0.052, 95% CI [0.017, 0.087], OR = 1.053, 95% CI [1.017, 1.091]). Both age and DL contamination emerged as consistent predictors of CDT performance. CONCLUSIONS: The clinical validity of CDT may be deteriorating. This study provides updated norms with optional DL adjustments. Their effectiveness in decreasing misclassifications requires diagnostic studies involving clinical samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Education, Psychology and Communication, Suor Orsola Benincasa University, Naples, Italy.
- Laboratoire d'Étude des Mécanismes Cognitifs, Université Lyon 2, Lyon, France; Institut Universitaire de France, Paris, France. Electronic address: francois.osiurak@univ-lyon2.fr.
- Neurological Unit, CTO Hospital, AORN "Ospedali Dei Colli", Naples, Italy.
- Department of Psychology and Health Sciences, Pegaso University, Naples, Italy.
- Department of Humanities, Federico II University, Naples, Italy.
Zitieren
APA
Ilardi, C. R., Osiurak, F., Gamboz, N., Iavarone, A., Scuotto, C., Marangolo, P., Brandimonte, M. A., De Luca, M., Garofalo, E., & Federico, G. (2026). Digital-like contamination in the Clock Drawing Test: Norms across six scoring systems. Journal of the Neurological Sciences, 491, 126239. https://doi.org/10.1016/j.jns.2026.126239
Vancouver
Ilardi CR, Osiurak F, Gamboz N, Iavarone A, Scuotto C, Marangolo P, et al. Digital-like contamination in the Clock Drawing Test: Norms across six scoring systems. Journal of the Neurological Sciences. 2026;491:126239. doi:10.1016/j.jns.2026.126239
BibTeX
@article{Ilardi2026,
author = {Ilardi, Ciro Rosario and Osiurak, François and Gamboz, Nadia and Iavarone, Alessandro and Scuotto, Chiara and Marangolo, Paola and Brandimonte, Maria Antonella and De Luca, Mariagiovanna and Garofalo, Elisabetta and Federico, Giovanni},
title = {Digital-like contamination in the Clock Drawing Test: Norms across six scoring systems},
journal = {Journal of the Neurological Sciences},
year = {2026},
volume = {491},
pages = {126239},
doi = {10.1016/j.jns.2026.126239}
}
EUVIMED