Spectral change or Jensen gap? Log-ratio baseline correction for time-frequency M/EEG is negatively biased
Journal of Neuroscience Methods · 2026-10 · 434 · 110826
DOI: 10.1016/j.jneumeth.2026.110826 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2026-10. Verfasst von Isaac Kinley und 3 weiteren Autor:innen. Beteiligte Einrichtung: Rotman Research Institute, Baycrest Academy for Research and Education, North York, Canada. Electronic address: ikinley@research.baycrest.org. Hauptthemen laut MEDLINE: Electroencephalography, Signal Processing, Computer-Assisted, Brain. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Time-frequency M/EEG analysis generally involves baseline correction to measure spectral changes following events of interest. The decibel or "log-ratio" baseline correction method divides spectral power in a target time window by average baseline power and log-transforms this ratio. This approach has several desirable properties and is ubiquitously available in popular software tools. However, we show that due to the concavity of the logarithm function, it follows from Jensen's inequality that log-ratio baseline correction is negatively biased, falsely indicating a decrease in spectral power when none exists. NEW METHOD We propose an unbiased alternative to log-ratio correction in which mean log-transformed baseline power is subtracted from log-transformed power in a target time window. This "mean-log-ratio" approach preserves the advantages of log-ratio correction without bias is easily implemented. RESULTS Using real and simulated data, we find that log-ratio baseline correction can cause true increases in spectral power to be incorrectly measured as decreases. This downward bias is evident across software implementations of this correction method. COMPARISON WITH EXISTING METHODS Whereas downward bias was evident for log-ratio baseline correction, simple mean-subtraction correction (in which mean baseline power is subtracted) was not biased. Similarly, our proposed mean-log-ratio method faithfully reflected true increases in spectral power. CONCLUSIONS We recommend against log-ratio baseline correction due to its negative bias. Even when analyses primarily examine differences between conditions rather than absolute spectral change from baseline, a biased baseline correction method can influence how results are interpreted. For researchers compelled by the advantages of log-ratio correction, we recommend mean-log-ratio correction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Rotman Research Institute, Baycrest Academy for Research and Education, North York, Canada. Electronic address: ikinley@research.baycrest.org.
- School of Psychology, University of Auckland, Auckland, New Zealand.
- Rotman Research Institute, Baycrest Academy for Research and Education, North York, Canada; Department of Psychology, University of Toronto, Toronto, Canada.
- Rotman Research Institute, Baycrest Academy for Research and Education, North York, Canada; School of Psychology, University of Auckland, Auckland, New Zealand; Department of Psychology, University of Toronto, Toronto,…
Zitieren
APA
Kinley, I., Roberts, R. P., Meltzer, J. A., & Addis, D. R. (2026). Spectral change or Jensen gap? Log-ratio baseline correction for time-frequency M/EEG is negatively biased. Journal of Neuroscience Methods, 434, 110826. https://doi.org/10.1016/j.jneumeth.2026.110826
Vancouver
Kinley I, Roberts RP, Meltzer JA, Addis DR. Spectral change or Jensen gap? Log-ratio baseline correction for time-frequency M/EEG is negatively biased. Journal of Neuroscience Methods. 2026;434:110826. doi:10.1016/j.jneumeth.2026.110826
BibTeX
@article{Kinley2026,
author = {Kinley, Isaac and Roberts, Reece P and Meltzer, Jed A and Addis, Donna Rose},
title = {Spectral change or Jensen gap? Log-ratio baseline correction for time-frequency M/EEG is negatively biased},
journal = {Journal of Neuroscience Methods},
year = {2026},
volume = {434},
pages = {110826},
doi = {10.1016/j.jneumeth.2026.110826}
}
EUVIMED