EUVIMEDEUVIMED entdecken
Open Access

Efficient coherence inference on complex time–frequency coefficients using a general linear model

Md Rakibul Mowla, Sukhbinder Kumar, Ariane E Rhone, Brian J Dlouhy, Christopher K Kovach

Journal of Neuroscience Methods · 2026

DOI: 10.1016/j.jneumeth.2026.110791 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2026. Verfasst von Md Rakibul Mowla und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University of Iowa, Iowa City, IA 52242, USA. Electronic address: mdrakibul-mowla@uiowa.edu. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted, Electroencephalography, Brain, Models, Neurological. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIDCD NIH HHS, National Institute of Neurological Disorders and Stroke.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Statistical significance testing of neural coherence is essential for distinguishing genuine cross-signal coupling from spurious correlations. Surrogate-based inference-typically using time shifts or phase randomization-is widely used but computationally expensive and produces discrete and sometimes unstable p-values, limiting scalability for large EEG/iEEG datasets. NEW METHOD: We introduce a parametric framework based on a general linear model (GLM) applied to complex-valued time-frequency coefficients (e.g., from the demodulated band transform or short-time Fourier transform). A likelihood ratio test provides continuous coherence significance estimates without surrogate resampling. RESULTS: Using real respiration traces as a driver and simulated neural signals with Gaussian broadband noise, we performed dense sweeps of ground-truth coherence. The GLM achieved sensitivity comparable to or better than surrogate testing and produced stable continuous p-values. At 80% detection power, the GLM detected coherence at C≈0.16, whereas surrogate testing required C≈0.31, corresponding to an ∼8 dB improvement in signal-to-noise ratio. Runtime benchmarking showed an ∼190× speed increase over surrogate-based methods. COMPARISON WITH EXISTING METHODS: Compared with time-shift and phase-randomization surrogates, the GLM provided matched or superior sensitivity while eliminating the permutation floor and dramatically reducing computation, particularly for dense frequency grids and multichannel datasets. CONCLUSIONS: GLM-based inference offers a robust, statistically principled, and computationally scalable alternative to surrogate-based coherence testing, enabling efficient analysis across channels, frequencies, and participants in large EEG/iEEG studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal Processing, Computer-AssistedElectroencephalographyBrainModels, NeurologicalLinear ModelsHumansComputer SimulationFourier AnalysisSignal-To-Noise RatioAlgorithmsTime FactorsRespiration

Stichwörter der Autor:innen

Circular time shiftDemodulated band transform (DBT)General linear model (GLM)Neural coherencePhase randomizationSurrogate testing

Autor:innen und Institutionen

  • Department of Neurosurgery, University of Iowa, Iowa City, IA 52242, USA. Electronic address: mdrakibul-mowla@uiowa.edu.
  • Department of Neurosurgery, University of Iowa, Iowa City, IA 52242, USA. Electronic address: sukhbinder-kumar@uiowa.edu.
  • Department of Neurosurgery, University of Iowa, Iowa City, IA 52242, USA. Electronic address: ariane-rhone@uiowa.edu.
  • Department of Neurosurgery, University of Iowa, Iowa City, IA 52242, USA; Department of Pediatrics, University of Iowa, Iowa City, IA 52242, USA. Electronic address: brian-dlouhy@uiowa.edu.
  • Department of Neurosurgery, University of Nebraska Medical Center, Omaha, NE 68198, USA. Electronic address: ckovach@unmc.edu.

Förderung

  • NINDS NIH HHS
  • NIDCD NIH HHS
  • National Institute of Neurological Disorders and Stroke
  • National Institute on Deafness and Other Communication Disorders

Zitieren

APA

Mowla, M. R., Kumar, S., Rhone, A. E., Dlouhy, B. J., & Kovach, C. K. (2026). Efficient coherence inference on complex time–frequency coefficients using a general linear model. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2026.110791

Vancouver

Mowla MR, Kumar S, Rhone AE, Dlouhy BJ, Kovach CK. Efficient coherence inference on complex time–frequency coefficients using a general linear model. Journal of Neuroscience Methods. 2026. doi:10.1016/j.jneumeth.2026.110791

BibTeX
@article{Mowla2026,
  author = {Mowla, Md Rakibul and Kumar, Sukhbinder and Rhone, Ariane E and Dlouhy, Brian J and Kovach, Christopher K},
  title = {Efficient coherence inference on complex time–frequency coefficients using a general linear model},
  journal = {Journal of Neuroscience Methods},
  year = {2026},
  doi = {10.1016/j.jneumeth.2026.110791}
}
Kostenlos starten →