Optimizing stereotaxic injection strategy for AAV-mediated corticospinal tract tracing in mice
Journal of Neuroscience Methods · 2026
DOI: 10.1016/j.jneumeth.2026.110679 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2026. Verfasst von Wei Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, PR China; Shandong University Ce…. Hauptthemen laut MEDLINE: Pyramidal Tracts, Dependovirus, Stereotaxic Techniques, Neuroanatomical Tract-Tracing Techniques. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shandong Provincial Postdoctoral Science Foundation, Shandong Province Department of Science and Technology.
Abstract (Originalsprache)
BACKGROUND: The corticospinal tract (CST) is a major descending motor pathway essential for voluntary motor control. While adeno-associated virus-mediated anterograde tracing is widely used to label CST projections in mice, what the best stereotaxic injection coordinates and post-injection intervals remain unclear. NEW METHOD: Here, we systematically evaluated eight cortical injection strategies, differing in anterior-posterior (AP) and medial-lateral (ML) coordinates, the number of injection sites, and post-injection intervals. CST labeling was quantitatively assessed at cervical 2, cervical 5, thoracic 2, thoracic 6, and lumbar 2 spinal levels using transduced axon count (TAC), mean fluorescence intensity (MFI) and transduced area within the dorsal columns, normalized to the C2 segment. RESULTS: Across the tested AP/ML coordinates and single- versus multi-site injections, TAC and MFI were broadly comparable across cervical and thoracic levels, with the exception of reduced L2 labeling in Group IV (AP +0.70 mm). Furthermore, reducing the post-injection interval from four weeks to two weeks did not compromise labeling efficiency. COMPARISON WITH EXISTING METHODS: Conventional CST tracing typically requires multiple injections and ≥ 4-week intervals, increasing complexity and duration. Our optimized single-injection, 2-week protocol achieves comparable labeling fidelity while reducing procedural burden and improving reproducibility. CONCLUSION: We suggest that effective CST labeling from L2 and rostral segments can be achieved with a single-point injection at AP coordinates between 0.0 and + 0.7 mm (ML fixed at 1.2 mm) or ML coordinates from + 0.7 to + 1.5 mm (AP fixed at 0.0 mm). These results establish a simplified, reproducible strategy for CST tracing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, PR China; Shandong University Centre for Orthopaedics, Advanced Medical Research Institute, Cheeloo Co…
- Department of Orthopaedics, The Second Qilu Hospital of Shandong University, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, PR China; Shandong University Centre for Orthopaedics, Advanced Medi…
- Henan Medical Key Laboratory for Research of Trauma and Orthopedics, The Third Affiliated Hospital of Xinxiang Medical University, Xinxiang, PR China. Electronic address: jliu@icord.org.
- Department of Orthopaedics, The Second Qilu Hospital of Shandong University, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, PR China. Electronic address: shj94@email.sdu.edu.cn.
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, PR China; Department of Orthopaedics, The Second Qilu Hospital of Shandong University, Cheeloo College…
Förderung
- National Natural Science Foundation of China
- Shandong Provincial Postdoctoral Science Foundation
- Shandong Province Department of Science and Technology
- Shandong University
Zitieren
APA
Wang, W., Zhang, T., Li, S., Wang, W., Jin, Q., Zhang, C., Liu, J., Sun, H., & Feng, S. (2026). Optimizing stereotaxic injection strategy for AAV-mediated corticospinal tract tracing in mice. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2026.110679
Vancouver
Wang W, Zhang T, Li S, Wang W, Jin Q, Zhang C, et al. Optimizing stereotaxic injection strategy for AAV-mediated corticospinal tract tracing in mice. Journal of Neuroscience Methods. 2026. doi:10.1016/j.jneumeth.2026.110679
BibTeX
@article{Wang2026,
author = {Wang, Wei and Zhang, Tehan and Li, Shaolong and Wang, Wenzhao and Jin, Quanhe and Zhang, Chi and Liu, Jie and Sun, Haijian and Feng, Shiqing},
title = {Optimizing stereotaxic injection strategy for AAV-mediated corticospinal tract tracing in mice},
journal = {Journal of Neuroscience Methods},
year = {2026},
doi = {10.1016/j.jneumeth.2026.110679}
}
EUVIMED