The impact of simultaneous intracranial recordings on scalp EEG: A finite element analysis
Journal of Neuroscience Methods · 2024-05 · 405 · 110101
DOI: 10.1016/j.jneumeth.2024.110101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroscience Methods, 2024-05. Verfasst von Simeon M Wong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Neurosciences and Mental Health, Hospital for Sick Children, Toronto, Canada; Institute of Biomedical Engineering, University of Toronto, Toronto, Ca…. Hauptthemen laut MEDLINE: Scalp, Epilepsy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: CIHR, Canadian Institutes of Health Research.
Abstract (Originalsprache)
BACKGROUND: In this study, we examined the utility of simultaneous scalp and stereotactic intracranial electroencephalography (SSIEEG) in epilepsy patients. Although SSIEEG offers valuable insights into epilepsy and cognitive function, its routine use is uncommon. Challenges include interpreting post-craniotomy scalp EEG due to surgically implanted electrodes. NEW METHOD: We describe our methodology for conducting SSIEEG recordings. To simulate the potential impact on EEG interpretation, we computed the leadfield of scalp electrodes with and without burrholes using Finite Element Analysis to compare the resulting sensitivity volume and waveforms of simulated intracranial signals between skulls with and without burrholes. RESULTS: The presence of burr holes in the skull layer of the leadfield models did not discernibly modify simulated waveforms or scalp EEG topology. Using realistic SEEG burr hole diameter, the difference in the average leadfield of scalp electrodes was 0.12% relative to the effect of switching two nearby electrodes, characterized by the cosine similarity difference. No patients experienced adverse events related to SSIEEG. COMPARISON WITH EXISTING METHODS: Although there is increasing acceptance and interest in SSIEEG, few studies have characterized the technical feasibility. Here, we demonstrate through modelling that scalp recordings from SSIEEG are comparable to that through an intact skull. CONCLUSION: The placement and simultaneous acquisition of scalp EEG during invasive monitoring through stereotactically inserted EEG electrodes is routinely performed at the Hospital for Sick Children. Scalp EEG recordings may assist with clinical interpretation. Burr holes in the skull layer did not discernibly alter EEG waveforms or topology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neurosciences and Mental Health, Hospital for Sick Children, Toronto, Canada; Institute of Biomedical Engineering, University of Toronto, Toronto, Canada.
- Department of Neurology, Hospital for Sick Children, Toronto, Canada.
- Neurosciences and Mental Health, Hospital for Sick Children, Toronto, Canada; Institute of Biomedical Engineering, University of Toronto, Toronto, Canada; Division of Neurosurgery, Hospital for Sick Children, Toronto, C…
Förderung
- CIHR
- Canadian Institutes of Health Research
Zitieren
APA
Wong, S. M., Sharma, R., Abushama, A., Ochi, A., Otsubo, H., & Ibrahim, G. M. (2024). The impact of simultaneous intracranial recordings on scalp EEG: A finite element analysis. Journal of Neuroscience Methods, 405, 110101. https://doi.org/10.1016/j.jneumeth.2024.110101
Vancouver
Wong SM, Sharma R, Abushama A, Ochi A, Otsubo H, Ibrahim GM. The impact of simultaneous intracranial recordings on scalp EEG: A finite element analysis. Journal of Neuroscience Methods. 2024;405:110101. doi:10.1016/j.jneumeth.2024.110101
BibTeX
@article{Wong2024,
author = {Wong, Simeon M and Sharma, Rohit and Abushama, Ahmed and Ochi, Ayako and Otsubo, Hiroshi and Ibrahim, George M},
title = {The impact of simultaneous intracranial recordings on scalp EEG: A finite element analysis},
journal = {Journal of Neuroscience Methods},
year = {2024},
volume = {405},
pages = {110101},
doi = {10.1016/j.jneumeth.2024.110101}
}
EUVIMED