EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Enhancing saliva diagnostics: The impact of amylase depletion on MALDI-ToF MS profiles as applied to COVID-19

Zane LaCasse, Prajkta Chivte, Kari Kress, Venkata Devesh R Seethi, Joshua Bland, Hamed Alhoori, Shrihari S Kadkol, Elizabeth R Gaillard

Journal of Mass Spectrometry and Advances in the Clinical Lab · 2024-01 · 31 · 59-71

DOI: 10.1016/j.jmsacl.2024.01.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mass Spectrometry and Advances in the Clinical Lab, 2024-01. Verfasst von Zane LaCasse und 7 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Chemistry and Biochemistry, Northern Illinois University, DeKalb, IL 60115, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Institute of Allergy and Infectious Diseases, Northern Illinois University, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Human saliva contains a wealth of proteins that can be monitored for disease diagnosis and progression. Saliva, which is easy to collect, has been extensively studied for the diagnosis of numerous systemic and infectious diseases. However, the presence of amylase, the most abundant protein in saliva, can obscure the detection of low-abundance proteins by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-ToF MS), thus reducing its diagnostic utility.

Objectives

In this study, we used a device to deplete salivary amylase from water-gargle samples by affinity adsorption. Following depletion, saliva proteome profiling was performed using MALDI-ToF MS on gargle samples from individuals confirmed to have COVID-19 based on nasopharyngeal (NP) swab reverse transcription quantitative polymerase chain reaction (RT-qPCR).

Results

The depletion of amylase led to increased signal intensities of various peaks and the detection of previously unobserved peaks in the MALDI-ToF MS spectra. The overall specificity and sensitivity after amylase depletion were 100% and 85.17%, respectively, for detecting COVID-19.

Conclusion

This simple, rapid, and inexpensive technique for depleting salivary amylase can reveal spectral diversity in saliva using MALDI-ToF MS, expose low-abundance proteins, and assist in establishing novel biomarkers for diseases.

Schlagwörter

Stichwörter der Autor:innen

AmylaseCOVID-19High-abundanceLow-abundanceMALDI-ToF MSSaliva

Autor:innen und Institutionen

  • Departments of Chemistry and Biochemistry, Northern Illinois University, DeKalb, IL 60115, USA.
  • Thermo Fisher Scientific, Rockford, IL 61101, USA.
  • Departments of Computer Science, Northern Illinois University, DeKalb, IL 60115, USA.
  • Department of Pathology, University of Illinois at Chicago, Chicago, IL 60612, USA.

Förderung

  • National Institute of Allergy and Infectious Diseases
  • Northern Illinois University
  • National Institutes of Health

Zitieren

APA

LaCasse, Z., Chivte, P., Kress, K., Seethi, V. D. R., Bland, J., Alhoori, H., Kadkol, S. S., & Gaillard, E. R. (2024). Enhancing saliva diagnostics: The impact of amylase depletion on MALDI-ToF MS profiles as applied to COVID-19. Journal of Mass Spectrometry and Advances in the Clinical Lab, 31, 59-71. https://doi.org/10.1016/j.jmsacl.2024.01.003

Vancouver

LaCasse Z, Chivte P, Kress K, Seethi VDR, Bland J, Alhoori H, et al. Enhancing saliva diagnostics: The impact of amylase depletion on MALDI-ToF MS profiles as applied to COVID-19. Journal of Mass Spectrometry and Advances in the Clinical Lab. 2024;31:59-71. doi:10.1016/j.jmsacl.2024.01.003

BibTeX
@article{LaCasse2024,
  author = {LaCasse, Zane and Chivte, Prajkta and Kress, Kari and Seethi, Venkata Devesh R and Bland, Joshua and Alhoori, Hamed and Kadkol, Shrihari S and Gaillard, Elizabeth R},
  title = {Enhancing saliva diagnostics: The impact of amylase depletion on MALDI-ToF MS profiles as applied to COVID-19},
  journal = {Journal of Mass Spectrometry and Advances in the Clinical Lab},
  year = {2024},
  volume = {31},
  pages = {59--71},
  doi = {10.1016/j.jmsacl.2024.01.003}
}
Kostenlos starten →