Measurement of kynurenine pathway metabolites by tandem mass spectrometry
Journal of Mass Spectrometry and Advances in the Clinical Lab · 2023-04 · 28 · 114-121
DOI: 10.1016/j.jmsacl.2023.04.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Mass Spectrometry and Advances in the Clinical Lab, 2023-04. Verfasst von Sedat Abusoglu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Recent studies have shown that derangements in kynurenine pathway metabolite levels are associated with various pathologies such as neurodegenerative diseases, schizophrenia, depression, bipolar disorder, rheumatoid arthritis, and cancer. Therefore, reliable, accurate, fast, and multiplex measurement methods for kynurenines have become increasingly important. This study aimed to validate a new mass spectrometric method for analyzing tryptophan metabolites.
Methods
A tandem mass spectrometric method, including protein precipitation and evaporation steps, was developed to measure serum levels of tryptophan, kynurenine, kynurenic acid, 3-hydroxykynurenine, and 3-hydroxyanthranilic acid. Samples were separated using a Phenomenex Luna C18 reversed-phase column. The kynurenine pathway metabolites were detected by tandem mass spectrometry. The developed method was validated according to Clinical & Laboratory Standards Institute (CLSI) guidelines and applied to hemodialysis samples.
Results
The developed method was linear at the concentrations of 48.8 - 25,000, 0.98 - 500, 1.2-5000, 1.2-5000, and 0.98-250 ng/mL for tryptophan, kynurenic acid, kynurenine, 3-hydroxyanthranilic acid, and 3-hydroxykynurenine, respectively. The imprecisions were less than 12 %. The median serum concentrations of tryptophan, kynurenine, kynurenic acid, 3-hydroxykynurenine, and 3-hydroxyanthranilic acid were 10530, 1100, 218, 17.6, and 25.4 ng/mL in pre-dialysis blood samples, respectively. They were 4560, 664, 135, 7.4, and 12.8 ng/mL in post-dialysis blood samples, respectively.
Conclusions
A fast, simple, cost-effective, accurate, robust, and validated tandem mass spectrometric method was developed, and the method was successfully used for the quantitation of kynurenine pathway metabolite concentrations in hemodialysis patients.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biochemistry, Selcuk University Faculty of Medicine, Konya, Turkey.
- Department of Medical Laboratory Techniques, Selcuk University Vocational School of Health, Konya, Turkey.
Zitieren
APA
Abusoglu, S., Eryavuz Onmaz, D., Abusoglu, G., Humeyra Yerlikaya, F., & Unlu, A. (2023). Measurement of kynurenine pathway metabolites by tandem mass spectrometry. Journal of Mass Spectrometry and Advances in the Clinical Lab, 28, 114-121. https://doi.org/10.1016/j.jmsacl.2023.04.003
Vancouver
Abusoglu S, Eryavuz Onmaz D, Abusoglu G, Humeyra Yerlikaya F, Unlu A. Measurement of kynurenine pathway metabolites by tandem mass spectrometry. Journal of Mass Spectrometry and Advances in the Clinical Lab. 2023;28:114-121. doi:10.1016/j.jmsacl.2023.04.003
BibTeX
@article{Abusoglu2023,
author = {Abusoglu, Sedat and Eryavuz Onmaz, Duygu and Abusoglu, Gulsum and Humeyra Yerlikaya, Fatma and Unlu, Ali},
title = {Measurement of kynurenine pathway metabolites by tandem mass spectrometry},
journal = {Journal of Mass Spectrometry and Advances in the Clinical Lab},
year = {2023},
volume = {28},
pages = {114--121},
doi = {10.1016/j.jmsacl.2023.04.003}
}
EUVIMED