Single-preparation spectroscopic exchange rate quantification using Turbo WEX and Turbo PS-WEX
Journal of Magnetic Resonance · 2026-10 · 391 · 108170
DOI: 10.1016/j.jmr.2026.108170 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance, 2026-10. Verfasst von N M J Plaehn und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Würzburg, Experimental Physics 5, Am Hubland, 97074 Würzburg, Germany. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Research Foundation.
Abstract (Originalsprache)
PURPOSE: The spectroscopic Water Exchange Filter (WEX) and its phase-sensitive variant PS-WEX allow quantification of the chemical exchange rate ksw. These methods selectively sample the solute pool magnetization, utilizing only a small fraction of the total prepared magnetization for signal generation. This work introduces Turbo WEX and Turbo PS-WEX, which acquire multiple readouts corresponding to different effective mixing times following a single preparation to substantially improve acquisition efficiency. METHODS: Repeated readouts of the solute pool after a single preparation enable accelerated sampling of the exchange process. Signal models for both methods were derived to allow quantitative exchange rate estimation. The approaches were demonstrated in single-preparation spectroscopy and as a proof of principle in a spatially and spectrally resolved Turbo PS-WEX imaging experiment using a creatine and phosphocreatine phantom. The achievable acceleration is primarily limited by longitudinal relaxation of the solvent pool. RESULTS: Both Turbo WEX and Turbo PS-WEX enabled accurate exchange rate quantification from single-preparation measurements in creatine samples with several pH-values. The imaging experiment yielded spatially and spectrally resolved exchange rate maps of the multi-compartment phantom. CONCLUSION: Multi-readout turbo acquisition substantially increases the efficiency of WEX-type experiments while preserving the ability to quantify exchange rates with spectral resolution. Reusing the magnetization from a single-preparation reduces the acquisition time for the spectroscopic measurement to less than five seconds, transforming WEX from a multi-minute experiment into a rapid quantitative tool.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Würzburg, Experimental Physics 5, Am Hubland, 97074 Würzburg, Germany.
- University of Würzburg, Experimental Physics 5, Am Hubland, 97074 Würzburg, Germany; Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Correnstrasse 3, 06466 Gatersleben, Germany.
- University of Würzburg, Experimental Physics 5, Am Hubland, 97074 Würzburg, Germany; Department of Neuroradiology, University Hospital of Würzburg, Josef-Schneider-Straße 11, Haus B1, 97080 Würzburg, Germany.
- University of Würzburg, Experimental Physics 5, Am Hubland, 97074 Würzburg, Germany. Electronic address: Fabian.Gutjahr@uni-wuerzburg.de.
Förderung
- German Research Foundation
Zitieren
APA
Plaehn, N. M. J., Balling, J., Kampf, T., Mayer, S., Jakob, P. M., & Gutjahr, F. T. (2026). Single-preparation spectroscopic exchange rate quantification using Turbo WEX and Turbo PS-WEX. Journal of Magnetic Resonance, 391, 108170. https://doi.org/10.1016/j.jmr.2026.108170
Vancouver
Plaehn NMJ, Balling J, Kampf T, Mayer S, Jakob PM, Gutjahr FT. Single-preparation spectroscopic exchange rate quantification using Turbo WEX and Turbo PS-WEX. Journal of Magnetic Resonance. 2026;391:108170. doi:10.1016/j.jmr.2026.108170
BibTeX
@article{Plaehn2026,
author = {Plaehn, N M J and Balling, J and Kampf, T and Mayer, S and Jakob, P M and Gutjahr, F T},
title = {Single-preparation spectroscopic exchange rate quantification using Turbo WEX and Turbo PS-WEX},
journal = {Journal of Magnetic Resonance},
year = {2026},
volume = {391},
pages = {108170},
doi = {10.1016/j.jmr.2026.108170}
}
EUVIMED