EUVIMEDEUVIMED entdecken
FallberichtVideo/Audio

Robotic Exploration and Suture Removal Following Sacrospinous Ligament Suspension

Evrim Erdemoglu, Catherine Rowley, Sumin Oh, Johhny Yi

Journal of Minimally Invasive Gynecology · 2025

DOI: 10.1016/j.jmig.2025.02.008 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Minimally Invasive Gynecology, 2025. Verfasst von Evrim Erdemoglu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Gynecologic Surgery, Mayo Clinic, Arizona, USA (all authors); Department of Obstetrics and Gynecology, Suleyman Demirel Uni…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Ligaments, Suture Techniques, Abscess.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STUDY OBJECTIVE: To demonstrate a deep robotic dissection of the sacrospinous ligament because of a suture abscess after a failed vaginal approach. DESIGN: A stepwise demonstration of the procedure and critical anatomy with narrated video. SETTING: A tertiary care academic center. A 71-year-old patient with a pelvic abscess noted on magnetic resonance imaging with persistent vaginal bleeding after sacrospinous ligament suspension using permanent, multi-filament suture. Despite multiple vaginal attempts to remove the suture, the abscess and suture persisted. A decision was made to proceed with a robotic exploration. INTERVENTION: Sacrospinous ligament suspension is a procedure supporting the vaginal apex by securing it to the sacrospinous ligament, typically on the right side. It is a durable, native tissue repair performed through extraperitoneal vaginal dissection of the pararectal space. With suture-related complications, to release the stitch, a vaginal approach is often successful and less invasive. However, it may be challenging to dissect this plane because of adhesions and difficult visualization. In this video, we demonstrate a robotic-assisted abdominal approach developing the pararectal space and identifying deep pelvic space lesions when vaginal attempts have failed. The top-down approach offers better visualization of surrounding critical structures, overcoming the limitations of the vaginal approach with limited visualization. However, this requires advanced knowledge and comfort with deep retroperitoneal structures. CONCLUSION: The robotic approach offers an alternative to the vaginal approach and should be considered when the vaginal approach fails or is considered not feasible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresLigamentsSuture TechniquesAbscessSuturesPelvic Organ ProlapseGynecologic Surgical ProceduresHumansFemaleAgedVagina

Stichwörter der Autor:innen

Coccygeus musclePelvic painRobotic surgerySacrospinous ligament suspensionSacrospinous ligamentopexy

Autor:innen und Institutionen

  • Department of Medical and Gynecologic Surgery, Mayo Clinic, Arizona, USA (all authors); Department of Obstetrics and Gynecology, Suleyman Demirel University, Turkey (Dr. Erdemoglu). Electronic address: Erdemoglu.Evrim@m…
  • Department of Medical and Gynecologic Surgery, Mayo Clinic, Arizona, USA (all authors).
  • Department of Medical and Gynecologic Surgery, Mayo Clinic, Arizona, USA (all authors); Department of Obstetrics and Gynecology, Korea University Guro Hospital, Seoul, Republic of Korea (Dr. Oh).

Zitieren

APA

Erdemoglu, E., Rowley, C., Oh, S., & Yi, J. (2025). Robotic Exploration and Suture Removal Following Sacrospinous Ligament Suspension. Journal of Minimally Invasive Gynecology. https://doi.org/10.1016/j.jmig.2025.02.008

Vancouver

Erdemoglu E, Rowley C, Oh S, Yi J. Robotic Exploration and Suture Removal Following Sacrospinous Ligament Suspension. Journal of Minimally Invasive Gynecology. 2025. doi:10.1016/j.jmig.2025.02.008

BibTeX
@article{Erdemoglu2025,
  author = {Erdemoglu, Evrim and Rowley, Catherine and Oh, Sumin and Yi, Johhny},
  title = {Robotic Exploration and Suture Removal Following Sacrospinous Ligament Suspension},
  journal = {Journal of Minimally Invasive Gynecology},
  year = {2025},
  doi = {10.1016/j.jmig.2025.02.008}
}
Kostenlos starten →