EUVIMEDEUVIMED entdecken
Crossref

A shellfish-inspired bionic microstructure design for biological implants: Enhancing protection of antibacterial silver-loaded coatings and promoting osseointegration

Jionghong Liang, Aiyi Chen, Ming Wu, Xiaolong Tang, Haixing Feng, Jiangwen Liu, Guie Xie

Journal of the Mechanical Behavior of Biomedical Materials · 2025-07 · 167 · 106963

DOI: 10.1016/j.jmbbm.2025.106963 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Mechanical Behavior of Biomedical Materials, 2025-07. Verfasst von Jionghong Liang und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou, 510006, PR China. Hauptthemen laut MEDLINE: Anti-Bacterial Agents, Silver, Coated Materials, Biocompatible, Osseointegration. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangdong Provincial Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implants incorporating multi-level micro-nano structures and antibacterial coatings offer a promising approach to overcoming the shortcomings of titanium and its alloys in stimulating bone growth and preventing bacterial infections. Silver ions have been identified as promising antibacterial agents. However, silver-loaded surface coatings are susceptible to damage from direct friction, and excessive release of silver ions can lead to cytotoxicity, thereby limiting their practical application. Inspired by the wear-resistant surface structure of natural shellfish, this study developed a biomimetic micro/nano multi-level structure on the titanium alloy (TC4) surfaces. The structure incorporated a biomimetic microgroove structure (BMS) with alkaline heat treatment (AH) of sodium titanate and chitosan/silver (CS/Ag) micro-nanostructured coatings (BMS/AH/CS/Ag). The microstructural armor effectively reduced external mechanical friction, safeguarding the coatings from damage. Compared to the unstructured sample, the biomimetic micro-groove armor group with a large micro-groove angle (θ) exhibited significantly reduced wear volume and only a marginal decrease of 1.86% in inhibition against Staphylococcus aureus (S. aureus) post-wear, highlighting the protective effect of this microstructure on the coating. The outstanding improvement was primarily attributed to the increased micro-groove angle, which enhanced the stability of the microstructure and effectively mitigated the friction. Additionally, the biomimetic micro-nano multi-level structure and coating have shown a significant ability to improve the bioactivity for the implant, promoting the adhesion, proliferation, collagen secretion, and extracellular matrix mineralization of human mesenchymal stem cells (hMSCs), which suggests the potential for enhanced osteogenic differentiation and indicates that this method can effectively improve the clinical performance of the implant.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anti-Bacterial AgentsSilverCoated Materials, BiocompatibleOsseointegrationProstheses and ImplantsBionicsBiomimetic MaterialsStaphylococcus aureusAnimalsMesenchymal Stem CellsHumansTitanium

Stichwörter der Autor:innen

AntibacterialBiocompatibilityBiomimetic structureMulti-level micro/nanostructuresOsteogenic differentiationSilver-loaded coatingsTitanium implants

Substanzen

Anti-Bacterial AgentsSilverCoated Materials, BiocompatibleTitanium

Autor:innen und Institutionen

  • State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou, 510006, PR China.
  • Guangzhou Key Laboratory for Clinical Rapid Diagnosis and Early Warning of Infectious Diseases, KingMed School of Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510182, PR China.
  • Department of Computer Science, KU Leuven, 3001, Leuven, Belgium; Department of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
  • State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou, 510006, PR China. Electronic address: fejwliu@scut.edu.cn.
  • Guangzhou Key Laboratory for Clinical Rapid Diagnosis and Early Warning of Infectious Diseases, KingMed School of Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510182, PR China. Electronic address: guier…

Förderung

  • National Natural Science Foundation of China
  • Guangdong Provincial Natural Science Foundation

Zitieren

APA

Liang, J., Chen, A., Wu, M., Tang, X., Feng, H., Liu, J., & Xie, G. (2025). A shellfish-inspired bionic microstructure design for biological implants: Enhancing protection of antibacterial silver-loaded coatings and promoting osseointegration. Journal of the Mechanical Behavior of Biomedical Materials, 167, 106963. https://doi.org/10.1016/j.jmbbm.2025.106963

Vancouver

Liang J, Chen A, Wu M, Tang X, Feng H, Liu J, et al. A shellfish-inspired bionic microstructure design for biological implants: Enhancing protection of antibacterial silver-loaded coatings and promoting osseointegration. Journal of the Mechanical Behavior of Biomedical Materials. 2025;167:106963. doi:10.1016/j.jmbbm.2025.106963

BibTeX
@article{Liang2025,
  author = {Liang, Jionghong and Chen, Aiyi and Wu, Ming and Tang, Xiaolong and Feng, Haixing and Liu, Jiangwen and Xie, Guie},
  title = {A shellfish-inspired bionic microstructure design for biological implants: Enhancing protection of antibacterial silver-loaded coatings and promoting osseointegration},
  journal = {Journal of the Mechanical Behavior of Biomedical Materials},
  year = {2025},
  volume = {167},
  pages = {106963},
  doi = {10.1016/j.jmbbm.2025.106963}
}
Kostenlos starten →