Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures

Juliet A Shepherd, Serena M Best, Ruth E Cameron

Journal of the Mechanical Behavior of Biomedical Materials · 2025

DOI: 10.1016/j.jmbbm.2025.106960 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Mechanical Behavior of Biomedical Materials, 2025. Verfasst von Juliet A Shepherd und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cambridge Centre for Medical Materials, Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge, …. Hauptthemen laut MEDLINE: Polypropylenes, Printing, Three-Dimensional, Mechanical Phenomena. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Cambridge, Wellcome-MRC Cambridge Stem Cell Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Auxetic structures studied in the literature are often based on relatively stiff, metallic materials and theories regarding their response to mechanical loading cannot be translated directly to polymeric materials. As “soft” auxetics increase in popularity for applications in tissue engineering further investigation into the joint behaviour and effect on their Poisson's ratio is required. 3D printed polypropylene auxetic mesh structures were produced to compare to the requirements for biological cell-stretching devices while investigating the deformation mechanics. The behaviour of the meshes was characterised with tensile force-strain curves and high-definition imaging and the effect of joint behaviour on the Poisson's ratio was evaluated. Isolated unit cell samples of the re-entrant mesh were produced to characterise the in- and out-of-plane behaviour for geometries comprising re-entrant strut angles of 30, 45, and 60° to the tensile straining direction. Force-strain curves with three distinct phases were observed, with linear, plateau, and terminal regions characteristic of re-entrant honeycomb structures. A constant negative Poisson's ratio was measured up to a critical transition strain, at which point it is theorised that the onset of buckling triggers bending-dominated deformation to occur, out-of-plane. The production of full-scale mesh samples with the same 30, 45, and 60° geometry resulted in consistent values for critical transition strain and Poisson's ratios. An auxetic region of strain was defined, where the force is linear and a homogeneous negative Poisson's ratio can be maintained. This region represents the limit within which a biological cell-stretching device could operate successfully for the current mesh design. • 3 stages of deformation: elastic, plastic bending, and stretching, shown by re-entrant unit cells made from 3D printed PP. • The critical transition from elastic to plastic bending prompted out-of-plane movement via strut buckling. • Constant negative Poisson's ratios were exhibited prior to the critical transition. • Auxetic structures produced well-defined homogenous strain profiles desirable for biological cell-stretching devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolypropylenesPrinting, Three-DimensionalMechanical PhenomenaMaterials TestingStress, MechanicalTensile Strength

Stichwörter der Autor:innen

3D-printingAuxetic deformationCell-stretchingOut-of-planePoisson's ratioPolypropyleneRe-entrant unit cell

Substanzen

Polypropylenes

Autor:innen und Institutionen

  • Cambridge Centre for Medical Materials, Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge, CB3 0FS, UK.
  • Cambridge Centre for Medical Materials, Department of Materials Science and Metallurgy, University of Cambridge, 27 Charles Babbage Road, Cambridge, CB3 0FS, UK. Electronic address: smb51@cam.ac.uk.

Förderung

  • University of Cambridge
  • Wellcome-MRC Cambridge Stem Cell Institute

Zitieren

APA

Shepherd, J. A., Best, S. M., & Cameron, R. E. (2025). Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2025.106960

Vancouver

Shepherd JA, Best SM, Cameron RE. Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures. Journal of the Mechanical Behavior of Biomedical Materials. 2025. doi:10.1016/j.jmbbm.2025.106960

BibTeX
@article{Shepherd2025,
  author = {Shepherd, Juliet A and Best, Serena M and Cameron, Ruth E},
  title = {Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures},
  journal = {Journal of the Mechanical Behavior of Biomedical Materials},
  year = {2025},
  doi = {10.1016/j.jmbbm.2025.106960}
}
Kostenlos starten →