EUVIMEDEUVIMED entdecken
Crossref

Design and feasibility testing of an automated custom finger orthosis for virtual therapy

Drew Miles, Yonas Tadesse

Journal of Hand Therapy · 2026-04

DOI: 10.1016/j.jht.2026.01.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hand Therapy, 2026-04. Verfasst von Drew Miles und 1 weiteren Autor:innen. Beteiligte Einrichtung: Humanoid, Biorobotics and Smart Systems (HBS Lab), Mechanical Engineering Department, Erik Jonsson School of Engineering and Computer Science, The Un…. Die Arbeit nennt 66 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND 3D printing has revolutionized orthoses manufacturing in assistive technologies, enabling development of custom-fitted orthoses in under 24 hours. Physician-engineer collaboration is essential to addressing the mechanical complexities of automated orthoses design. Single-step manufacturing of these devices is necessary for simplistic and translational technologies. PURPOSE This work proposes a novel automated program, application programing interface, to design a custom single-finger orthosis using only basic biometric data (body weight, height, and age) as input to enable fully virtual rehabilitation. STUDY DESIGN Feasibility study, cross-sectional design, and survey study. METHODS Customization without body scans streamlines programming and enables gross estimate of hand orthosis size. Computer-aided design models are automatically generated using the Automated Custom Finger Orthoses system that was created using several macros with SolidWorks and Visual Basic Editor. A military database was used for the biometric data for the program to establish a relationship between finger size and biometric data. Survey data were taken from 10 human healthy participants (six male and four female, aged between 18 and 60) using Likert scales to check fitness of 3D-printed soft index finger orthosis part. RESULTS Computer-aided design models were successfully created using the application programing interface using military database, the models were 3D-printed and fitted on subjects. The fitness of the device varies significantly under the current parameters. Eight of the 10 test devices fit their test subjects with overall average offsets of 7.00 mm, 6.14 mm, and 8.89 mm for DIP (L1), PIP (L2), and MCP joints (L3 offset), respectively and the subjects were fully donned. The biasing of current data toward male subjects results in slightly better fit accuracy in males than in females. CONCLUSIONS Anthropometric studies can aid in discerning fundamental ratios for orthoses design, allowing for custom-fitted designs and manufacturing with ease and efficiency.

Schlagwörter

Stichwörter der Autor:innen

APIAutomated designCADHand orthosesStroke therapyTelehealth

Autor:innen und Institutionen

  • Humanoid, Biorobotics and Smart Systems (HBS Lab), Mechanical Engineering Department, Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas (UTD), Richardson, TX, USA.
  • Humanoid, Biorobotics and Smart Systems (HBS Lab), Mechanical Engineering Department, Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas (UTD), Richardson, TX, USA; Electrical Eng…

Zitieren

APA

Miles, D., & Tadesse, Y. (2026). Design and feasibility testing of an automated custom finger orthosis for virtual therapy. Journal of Hand Therapy. https://doi.org/10.1016/j.jht.2026.01.004

Vancouver

Miles D, Tadesse Y. Design and feasibility testing of an automated custom finger orthosis for virtual therapy. Journal of Hand Therapy. 2026. doi:10.1016/j.jht.2026.01.004

BibTeX
@article{Miles2026,
  author = {Miles, Drew and Tadesse, Yonas},
  title = {Design and feasibility testing of an automated custom finger orthosis for virtual therapy},
  journal = {Journal of Hand Therapy},
  year = {2026},
  doi = {10.1016/j.jht.2026.01.004}
}