EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ortho-Monitorizer: A portable device for quantitative monitoring of temperature and pressure in a 3D-printed upper limb orthosis

Matilde Antão, Inês Rodrigues, Carla Quintão, Cláudia Quaresma

Journal of Hand Therapy · 2025-04 · 38 (2) · 266-277

DOI: 10.1016/j.jht.2025.03.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hand Therapy, 2025-04. Verfasst von Matilde Antão und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Carpal Tunnel Syndrome, Orthotic Devices, Pressure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Foundation for Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Adherence to wrist-hand orthoses in patients with musculoskeletal conditions, such as Carpal Tunnel Syndrome, is crucial for effective rehabilitation. However, objective methods for monitoring wear time and pressure distribution remain limited. PURPOSE: This study presents the Ortho-Monitorizer, a portable 3D-printed sensor-integrated device designed to provide real-time, quantitative monitoring of temperature and pressure in upper limb orthoses. The objective is to evaluate the system's feasibility in detecting patient adherence and identifying critical pressure points. STUDY DESIGN: A descriptive and cross-sectional study was conducted to develop and validate the device, including sensor integration and data acquisition. METHODS: Using a 3D scanner and Fusion 360 software, the orthoses were customized and printed in thermoplastic polyurethane. Data from healthy participants (n = 55) and patients with Carpal Tunnel Syndrome (n = 2) were collected through the Ortho-Monitorizer's application, using six sensors (three temperature and three pressure sensors) placed at clinically relevant anatomical points. Data were acquired over five hand positions, and normal reference values were established. RESULTS: Mean temperature values ranged between 29.5∘C and 32.5∘C, while pressure values varied from 0.00 MPa to 0.08 MPa across different hand positions. One CTS patient exhibited pressure values above normal thresholds in specific positions, correlating with discomfort and numbness reports. The device achieved a System Usability Scale (SUS) score of 86.8% (healthy participants) and 92.5% (CTS patients), indicating high usability and acceptance. CONCLUSIONS: The Ortho-Monitorizer provides a non-invasive, objective method for monitoring patient adherence to orthotic treatments. By offering real-time tracking of critical parameters, it enhances clinical decision-making and patient outcomes. Future research should explore wireless integration and long-term clinical validation to further optimize its applicability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalCarpal Tunnel SyndromeOrthotic DevicesPressureHumansCross-Sectional StudiesMaleFemaleAdultMiddle AgedEquipment DesignPatient ComplianceAgedMonitoring, PhysiologicUpper Extremity

Stichwörter der Autor:innen

3D printingMonitoringOrthosesRehabilitationSensorsUpper limb

Autor:innen und Institutionen

  • Department of Physics, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal.
  • Physical Medicine and Rehabilitation Area, Curry Cabral Hospital, Unidade Local de Saúde de São José, Lisboa, Portugal.
  • Department of Physics, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal; LIBPhys, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal.
  • Department of Physics, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal; LIBPhys, NOVA School of Science and Technology, NOVA University of Lisbon, Caparica, Portugal. Electronic addr…

Förderung

  • Foundation for Science and Technology

Zitieren

APA

Antão, M., Rodrigues, I., Quintão, C., & Quaresma, C. (2025). Ortho-Monitorizer: A portable device for quantitative monitoring of temperature and pressure in a 3D-printed upper limb orthosis. Journal of Hand Therapy, 38(2), 266-277. https://doi.org/10.1016/j.jht.2025.03.002

Vancouver

Antão M, Rodrigues I, Quintão C, Quaresma C. Ortho-Monitorizer: A portable device for quantitative monitoring of temperature and pressure in a 3D-printed upper limb orthosis. Journal of Hand Therapy. 2025;38(2):266-277. doi:10.1016/j.jht.2025.03.002

BibTeX
@article{Anto2025,
  author = {Antão, Matilde and Rodrigues, Inês and Quintão, Carla and Quaresma, Cláudia},
  title = {Ortho-Monitorizer: A portable device for quantitative monitoring of temperature and pressure in a 3D-printed upper limb orthosis},
  journal = {Journal of Hand Therapy},
  year = {2025},
  volume = {38},
  number = {2},
  pages = {266--277},
  doi = {10.1016/j.jht.2025.03.002}
}
Kostenlos starten →