Quantifying the reach-and-grasp practice using novel wearable technology: Application in a stroke rehabilitation setting
Journal of Hand Therapy · 2025
DOI: 10.1016/j.jht.2025.02.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Hand Therapy, 2025. Verfasst von Chieh-Ling Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Occupational Therapy, Chang Gung University, Taoyuan City, Taiwan; Department of Physical Medicine and Rehabilitation, Chang Gung Memor…. Hauptthemen laut MEDLINE: Stroke Rehabilitation, Wearable Electronic Devices, Hand Strength, Upper Extremity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Canadian Institutes of Health Research, Canada Research Chairs, National Science and Technology Council.
Themen: Schlaganfall
Abstract (Originalsprache)
BACKGROUND: Wrist-worn accelerometers have been used to measure the intensity of upper extremity (UE) practice, but their primary focus is on general arm usage, lacking the ability to capture reaching and grasping of the hand that are relevant for rehabilitation. PURPOSE: We aimed to explore the potential of a novel wrist-worn sensor as a meaningful measure for quantifying the amount of reaching and grasping practice during a structured UE exercise session for stroke. STUDY DESIGN: A cross-sectional study. METHODS: Fourteen individuals with stroke wore sensor devices (TENZR) on both wrists while performing a structured UE exercise program comprising of 35 exercises. Counts recorded from observation (observed repetitions) and counts from the sensor device (sensor counts) were used to describe the amount of UE practice. The level of agreement between the observed repetitions and sensor counts were examined to determine if the TENZR is a meaningful measure. We also explore if the sensor counts were affected by the level of UE impairment. RESULTS: The participants performed 792 observed reach and grasp repetitions, with corresponding 711 and 465 sensor counts for the paretic hand and nonparetic hand, respectively, over the hour practice session. The TENZR and the observational method might measure UE movement differently, as evidenced by a lack of agreement between observed repetitions and sensor counts in the paretic hand. No significant relationship between the sensor counts in the paretic hand and the level of impairment was found. CONCLUSIONS: This study used the TENZR to quantify reaching and grasping practice and characterize individual participation pattern for both paretic and nonparetic hands in stroke rehabilitation. The device is an alternative to direct observation for quantifying the intensity of reach-and-grasp practice. In the future, this device could expand to home-based rehabilitation and telehealth services, enabling objective monitoring and tracking of UE training progress.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Occupational Therapy, Chang Gung University, Taoyuan City, Taiwan; Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital, Chiayi, Taiwan; Department of Physical Therapy, Faculty…
- Department of Occupational Therapy, Chang Gung University, Taoyuan City, Taiwan.
- Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital, Chiayi, Taiwan.
- Biomedical and Mobile Health Technology Lab, Department of Health Sciences and Technology, ETH Zurich, Switzerland; MENRVA Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser…
- Department of Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; Centre for Aging SMART at Vancouver Coastal Health, Vancouver, British Columbia, Canada. Electron…
Förderung
- Canadian Institutes of Health Research
- Canada Research Chairs
- National Science and Technology Council
- Natural Sciences and Engineering Research Council of Canada
- National Health Research Institutes
Zitieren
APA
Yang, C. L., Cheng, Y. Y., Lin, C. H., Menon, C., & Eng, J. J. (2025). Quantifying the reach-and-grasp practice using novel wearable technology: Application in a stroke rehabilitation setting. Journal of Hand Therapy. https://doi.org/10.1016/j.jht.2025.02.017
Vancouver
Yang CL, Cheng YY, Lin CH, Menon C, Eng JJ. Quantifying the reach-and-grasp practice using novel wearable technology: Application in a stroke rehabilitation setting. Journal of Hand Therapy. 2025. doi:10.1016/j.jht.2025.02.017
BibTeX
@article{Yang2025,
author = {Yang, Chieh-Ling and Cheng, Ya-Yuan and Lin, Chu-Hsu and Menon, Carlo and Eng, Janice J},
title = {Quantifying the reach-and-grasp practice using novel wearable technology: Application in a stroke rehabilitation setting},
journal = {Journal of Hand Therapy},
year = {2025},
doi = {10.1016/j.jht.2025.02.017}
}
EUVIMED