EUVIMEDEUVIMED entdecken
Crossref

Reverse Total Wrist Arthroplasty: New Design and Biomechanical Advantages

Elizabeth Norman-Puim, Emily Lalone, Assaf Kadar, G Daniel G Langohr, Nina Suh

The Journal of Hand Surgery · 2026-11 · 51 (11) · 1163.e1-1163.e9

DOI: 10.1016/j.jhsa.2026.06.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Hand Surgery, 2026-11. Verfasst von Elizabeth Norman-Puim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, L…. Hauptthemen laut MEDLINE: Wrist Joint, Prosthesis Design, Arthroplasty, Replacement, Joint Prosthesis. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Although fourth generation total wrist arthroplasties (TWAs) have improved implant longevity compared to earlier generations, high failure rates persist. This study aimed to assess how a shift in the center of rotation will affect kinematic outcomes of the joint. This has been accomplished through a TWA redesign, known as the reverse total wrist arthroplasty (RTWA). METHODS: Eight cadaveric specimens (75.1 ± 10.9 years, 8 men) were implanted with both a custom load sensing TWA and a novel redesigned RTWA. For both reconstructed states, the specimens were mounted and actuated through flexion-extension (FE) and radial-ulnar deviation (RUD) using an active motion simulator. Muscle forces and articular loading patterns were recorded in both states for comparison of the implant designs. Statistical analysis completed showed RUD motion was underpowered and are therefore presented as exploratory and descriptive because of limited power. RESULTS: In general, during both FE and RUD the RTWA required a lower magnitude of force from the muscles compared to the TWA state. Throughout FE, four of the five muscles examined required less force after RTWA implantation. Through RUD, three of five required less force. In addition, through both ranges of motion the carpal component joint loading was decreased in all wrist positions (41.6 ± 8.6% and 38.1 ± 7.1% for extension and flexion motion, respectively) after implantation of the RTWA compared to the TWA. CONCLUSIONS: The redesigned RTWA performed well compared to a standard TWA implant and there was a noted decrease in both the muscle forces and joint loading following RTWA implantation. CLINICAL RELEVANCE: The new RTWA design may have the potential to reduce the magnitude of force required by muscles to actuate the joint and reduce the high loading patterns within the distal carpal component that are noted after implantation of TWA implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wrist JointProsthesis DesignArthroplasty, ReplacementJoint ProsthesisHumansBiomechanical PhenomenaRange of Motion, ArticularMaleAgedFemaleCadaverAged, 80 and over

Stichwörter der Autor:innen

Arthroplasty designjoint loadingreverse total wrist arthroplastywrist

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada. Electronic address: Enorman4@uwo.ca.
  • Department of Biomedical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada.
  • Department of Surgery, St. Joseph's Hospital, London, ON, Canada.
  • Department of Biomedical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London,…
  • Department of Surgery, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada; Department of Orthopaedics, Emory University, Atlanta, GA.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Norman-Puim, E., Lalone, E., Kadar, A., Langohr, G. D. G., & Suh, N. (2026). Reverse Total Wrist Arthroplasty: New Design and Biomechanical Advantages. The Journal of Hand Surgery, 51(11), 1163.e1-1163.e9. https://doi.org/10.1016/j.jhsa.2026.06.005

Vancouver

Norman-Puim E, Lalone E, Kadar A, Langohr GDG, Suh N. Reverse Total Wrist Arthroplasty: New Design and Biomechanical Advantages. The Journal of Hand Surgery. 2026;51(11):1163.e1-1163.e9. doi:10.1016/j.jhsa.2026.06.005

BibTeX
@article{NormanPuim2026,
  author = {Norman-Puim, Elizabeth and Lalone, Emily and Kadar, Assaf and Langohr, G Daniel G and Suh, Nina},
  title = {Reverse Total Wrist Arthroplasty: New Design and Biomechanical Advantages},
  journal = {The Journal of Hand Surgery},
  year = {2026},
  volume = {51},
  number = {11},
  pages = {1163.e1--1163.e9},
  doi = {10.1016/j.jhsa.2026.06.005}
}
Kostenlos starten →