EUVIMEDEUVIMED entdecken
Crossref

Reducing blood culture contamination in the emergency department through changes in sampling technique: an interrupted time-series analysis

J W Goodall, T Bradbury, A Crede, T Gamban, M Tovey, C Lynch, H Parsons

Journal of Hospital Infection · 2026-07 · 173 · 225-229

DOI: 10.1016/j.jhin.2026.05.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hospital Infection, 2026-07. Verfasst von J W Goodall und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Microbiology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK; The Florey Institute of Infection, Department …. Hauptthemen laut MEDLINE: Blood Culture, Emergency Service, Hospital, Specimen Handling, Equipment Contamination. Die Arbeit nennt 12 Literaturangaben. Gefördert von: NIHR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES Following implementation of a national guideline recommending two blood culture sets for patients with suspected sepsis, routine surveillance in our large tertiary emergency department identified increased contamination. We aimed to identify contributory sampling practices and evaluate a co-produced intervention to reduce contamination. METHODS We conducted a two-phase quality-improvement project. In phase one, blood cultures were prospectively labelled by sampling technique and compared by Chi-square testing. In phase two, a multidisciplinary team co-produced an intervention eliminating the technique most associated with contamination. Monthly contamination proportions were analysed using quasibinomial interrupted time-series regression, modelling step and slope changes at both guideline introduction and the intervention. Safety analyses examined effects on sampling rates, underfilled sample rates and true bacteraemia detection. RESULTS We analysed 20,263 blood cultures (January 2022-June 2025). The guideline's introduction was associated with an immediate rise in contamination (OR 1.56, 95% CI 1.15-2.12; p=0.005). Cannula-and-syringe sampling had higher contamination than other methods (25/238 [10.5%] vs 3/157 [1.9%]; p=0.002). Withdrawal of this method led to an immediate reduction (OR 0.49, 95% CI 0.36-0.66; p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood CultureEmergency Service, HospitalSpecimen HandlingEquipment ContaminationHumansInterrupted Time Series AnalysisBacteremiaQuality ImprovementProspective StudiesSepsis

Stichwörter der Autor:innen

Blood culturesContaminationEmergency medicine

Autor:innen und Institutionen

  • Department of Clinical Microbiology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK; The Florey Institute of Infection, Department of Clinical Medicine, The University of Sheffield, Sheffield, UK. Elec…
  • Department of Emergency Medicine, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
  • Department of Clinical Microbiology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.

Förderung

  • NIHR

Zitieren

APA

Goodall, J. W., Bradbury, T., Crede, A., Gamban, T., Tovey, M., Lynch, C., & Parsons, H. (2026). Reducing blood culture contamination in the emergency department through changes in sampling technique: an interrupted time-series analysis. Journal of Hospital Infection, 173, 225-229. https://doi.org/10.1016/j.jhin.2026.05.010

Vancouver

Goodall JW, Bradbury T, Crede A, Gamban T, Tovey M, Lynch C, et al. Reducing blood culture contamination in the emergency department through changes in sampling technique: an interrupted time-series analysis. Journal of Hospital Infection. 2026;173:225-229. doi:10.1016/j.jhin.2026.05.010

BibTeX
@article{Goodall2026,
  author = {Goodall, J W and Bradbury, T and Crede, A and Gamban, T and Tovey, M and Lynch, C and Parsons, H},
  title = {Reducing blood culture contamination in the emergency department through changes in sampling technique: an interrupted time-series analysis},
  journal = {Journal of Hospital Infection},
  year = {2026},
  volume = {173},
  pages = {225--229},
  doi = {10.1016/j.jhin.2026.05.010}
}
Kostenlos starten →