Evaluation of a rapid quality control method for endoscope cleaning
Journal of Hospital Infection · 2026
DOI: 10.1016/j.jhin.2025.11.033 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Hospital Infection, 2026. Verfasst von S Bulot und 1 weiteren Autor:innen. Beteiligte Einrichtung: Eurofins Biotech-Germande, Aix en Provence, France. Electronic address: suzy.bulot@etfr.eurofins.com. Hauptthemen laut MEDLINE: Endoscopes, Quality Control, Disinfection, Decontamination. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Over the past 30 years, endoscope processing has improved significantly, guided by various standards and recommendations. None the less, contamination remains an issue, with 21.1% of endoscopes exceeding acceptable thresholds in 2021. Cleaning, including pre-treatment, is identified as critical for successful endoscope processing. ISO 15883-5 and AAMI guidelines provide frameworks for evaluating cleaning efficacy, with ANSI/AAMI ST91 recommending verification of cleanliness for high-risk and complex-design endoscopes after each cycle. This study assesses the EndoCheck protein detection kit (HEALTHMARK) as a rapid test for evaluating cleaning quality in endoscope channels. METHODS: The study was conducted in two phases: (1) performance testing (detection limit, extraction efficiency, and sensitivity), and (2) real-use testing (comparison with a standard flush sampling method). RESULTS: The EndoCheck kit consistently detected ≥5 μg of bovine serum albumin (BSA) in polytetrafluoroethylene (PTFE) tubes, equivalent to 0.4 μg/cm2, and recovered an average of 68 ± 11% of the initial soil. Under real-use conditions, it identified 51% of endoscopes as non-compliant, compared with 14% with the flush method. This discrepancy was more pronounced in bronchoscopes, likely due to the nature of the residual soil. CONCLUSION: The EndoCheck kit is a highly sensitive, easy-to-use method for detecting residual protein in biopsy channels. Its greater stringency compared with current flush methods makes it a reliable tool for confirming cleanliness when results are negative. Positive results can serve as early indicators, prompting further investigation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Eurofins Biotech-Germande, Aix en Provence, France. Electronic address: suzy.bulot@etfr.eurofins.com.
- Eurofins Biotech-Germande, Aix en Provence, France.
Zitieren
APA
Bulot, S., & Pineau, L. (2026). Evaluation of a rapid quality control method for endoscope cleaning. Journal of Hospital Infection. https://doi.org/10.1016/j.jhin.2025.11.033
Vancouver
Bulot S, Pineau L. Evaluation of a rapid quality control method for endoscope cleaning. Journal of Hospital Infection. 2026. doi:10.1016/j.jhin.2025.11.033
BibTeX
@article{Bulot2026,
author = {Bulot, S and Pineau, L},
title = {Evaluation of a rapid quality control method for endoscope cleaning},
journal = {Journal of Hospital Infection},
year = {2026},
doi = {10.1016/j.jhin.2025.11.033}
}
EUVIMED