EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of air flow rate over time on SARS-CoV-2 viability during representative sampling using MD8 airport air sampler

I Nicholls, O Onianwa, S Collins, A Spencer, S Parks, B Atkinson, T Pottage

Journal of Hospital Infection · 2025

DOI: 10.1016/j.jhin.2025.06.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hospital Infection, 2025. Verfasst von I Nicholls und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biosafety Air and Water Microbiology Group, Diagnostics and Pathogen Characterisation, UK Health Security Agency, Porton Down, Salisbury, UK. Hauptthemen laut MEDLINE: SARS-CoV-2, Airports, COVID-19, Air Microbiology. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UK Health Security Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Studies involving air sampling for SARS-CoV-2 commonly return either negative data or non-viable virus. AIM: This study assessed the desiccative impact of time parameters during air sampling. METHODS: The study aerosolised SARS-CoV-2 on to gelatine Sartorius MD8 AirPort gelatin filters which were then attached to a Sartorius MD8 AirPort and run at 50 L/min up to 40 min. These filters were then analysed by viral plaque assay and quantitative reverse transcription-polymerase chain reaction. FINDINGS: There was no significant difference in recovery of infectious virus or genomic copy numbers with increasing air sampled. CONCLUSION: Sampling for ≤40 min with a Sartorius MD8 AirPort does not reduce the viability of SARS-CoV-2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2AirportsCOVID-19Air MicrobiologyMicrobial ViabilityHumansTime Factors

Stichwörter der Autor:innen

Air samplingDesiccationSARS-CoV-2Sartorius MD8 Airport

Autor:innen und Institutionen

  • Biosafety Air and Water Microbiology Group, Diagnostics and Pathogen Characterisation, UK Health Security Agency, Porton Down, Salisbury, UK.
  • Biosafety Air and Water Microbiology Group, Diagnostics and Pathogen Characterisation, UK Health Security Agency, Porton Down, Salisbury, UK; NIHR Health Protection Research Unit in Emerging Zoonotic Infections, UK.
  • Biosafety Air and Water Microbiology Group, Diagnostics and Pathogen Characterisation, UK Health Security Agency, Porton Down, Salisbury, UK. Electronic address: thomas.pottage@ukhsa.gov.uk.

Förderung

  • UK Health Security Agency

Zitieren

APA

Nicholls, I., Onianwa, O., Collins, S., Spencer, A., Parks, S., Atkinson, B., & Pottage, T. (2025). Effect of air flow rate over time on SARS-CoV-2 viability during representative sampling using MD8 airport air sampler. Journal of Hospital Infection. https://doi.org/10.1016/j.jhin.2025.06.002

Vancouver

Nicholls I, Onianwa O, Collins S, Spencer A, Parks S, Atkinson B, et al. Effect of air flow rate over time on SARS-CoV-2 viability during representative sampling using MD8 airport air sampler. Journal of Hospital Infection. 2025. doi:10.1016/j.jhin.2025.06.002

BibTeX
@article{Nicholls2025,
  author = {Nicholls, I and Onianwa, O and Collins, S and Spencer, A and Parks, S and Atkinson, B and Pottage, T},
  title = {Effect of air flow rate over time on SARS-CoV-2 viability during representative sampling using MD8 airport air sampler},
  journal = {Journal of Hospital Infection},
  year = {2025},
  doi = {10.1016/j.jhin.2025.06.002}
}
Kostenlos starten →