Effect of tissue adhesive application on central line-associated bloodstream infections: a multi-centre retrospective study
Journal of Hospital Infection · 2025
DOI: 10.1016/j.jhin.2025.04.030 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Hospital Infection, 2025. Verfasst von Y Kwon und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul 88 Clinic, Suwon, Gyeonggi-do, Republic of Korea. Hauptthemen laut MEDLINE: Catheter-Related Infections, Tissue Adhesives, Catheterization, Central Venous, Sepsis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Use of central venous access devices (CVADs) has been plagued by various adverse events, including central line-associated bloodstream infection (CLABSI), inadvertent dislocation, exit-site haemorrhage, and local infection. AIM: To investigate whether tissue adhesive (TA, 2-octyl blended with n-butyl cyanoacrylate) application to centrally/femorally inserted central catheter (CICC/FICC) exit sites could reduce the occurrence of CLABSI. METHODS: This retrospective review with historical controls was conducted in three tertiary care institutions. The TA group was established from December 2021 to July 2022 with the simultaneous initiation of TA application to the exit site of CICCs/FICCs. Patients in the control group received CICCs/FICCs before TA application between February 2021 and November 2021. Adverse event rates, including CLABSI, oozing, dislocation, and skin problems, were compared between groups. Risk factors were analysed using inverse probability of treatment weighting (IPTW)-adjusted Cox analysis. FINDINGS: The TA group comprised 1061 patients; the control group included 1049 patients. The CLABSI rate was significantly lower in the TA group (1.84 per 1000 catheter-days) compared with the control group (3.66 per 1000 catheter-days), with a rate ratio of 0.5 (95% confidence interval: 0.28-0.87; P = 0.01). The oozing rate was significantly lower (TA: 120; control: 158; P = 0.01). IPTW-adjusted analysis revealed TA as risk-reducing factor (P = 0.003), while age (P = 0.04) and triple-lumen (P = 0.04) were significant risk factors for CLABSI. CONCLUSION: TA application at CICCs/FICCs exit sites could significantly lower CLABSI rates without serious adverse events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Seoul 88 Clinic, Suwon, Gyeonggi-do, Republic of Korea.
- Department of Radiology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Electronic address: interv@catholic.ac.kr.
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Republic of Korea; Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul,…
- Department of Radiology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon-si, Gyeonggi-do, Republic of Korea.
- Department of Infectious Diseases, Ajou University Hospital, Ajou University School of Medicine, Suwon-si, Gyeonggi-do, Republic of Korea.
Zitieren
APA
Kwon, Y., Shim, D. J., Lee, J. H., Kim, D., Baek, S. H., Kim, J., Kim, E. J., Kim, Y. J., Choi, T. W., & Won, J. H. (2025). Effect of tissue adhesive application on central line-associated bloodstream infections: a multi-centre retrospective study. Journal of Hospital Infection. https://doi.org/10.1016/j.jhin.2025.04.030
Vancouver
Kwon Y, Shim DJ, Lee JH, Kim D, Baek SH, Kim J, et al. Effect of tissue adhesive application on central line-associated bloodstream infections: a multi-centre retrospective study. Journal of Hospital Infection. 2025. doi:10.1016/j.jhin.2025.04.030
BibTeX
@article{Kwon2025,
author = {Kwon, Y and Shim, D J and Lee, J H and Kim, D and Baek, S H and Kim, J and Kim, E J and Kim, Y J and Choi, T W and Won, J H},
title = {Effect of tissue adhesive application on central line-associated bloodstream infections: a multi-centre retrospective study},
journal = {Journal of Hospital Infection},
year = {2025},
doi = {10.1016/j.jhin.2025.04.030}
}