Influence of drying time on the removal of blood from medical devices

B R Wulff, S Lohse, M Tschoerner

Journal of Hospital Infection · 2024-10 · 152 · 156-163

DOI: 10.1016/j.jhin.2024.07.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hospital Infection, 2024-10. Verfasst von B R Wulff und 2 weiteren Autor:innen. Beteiligte Einrichtung: Chemische Fabrik Dr. Weigert GmbH & Co. KG, Hamburg, Germany. Electronic address: Bastian.Wulff@drweigert.de. Hauptthemen laut MEDLINE: Desiccation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: When processing surgical instruments after use, the safe, residue-free removal of blood and blood-containing soiling is one of the most important tasks. There are recommendations from various working groups regarding the ideal timeframe for cleaning used instruments in order to ensure safe disinfection and sterilization and avoid adverse effects. These are generally based primarily on practical experience and there is little systematic work on this topic. AIM: In the present study, cleaning experiments with test specimens previously contaminated with sheep's blood were performed, and in this way the effects of the drying time of whole blood on the results of the subsequent cleaning were examined. METHODS: Reflecting practice, both visual and spectroscopic methods were used to quantify residual protein. The experimental results were evaluated both as a function of the drying time and the residual moisture of the blood. FINDINGS: Drying blood was particularly difficult to remove within the first 1-2 h. In this phase, in which the blood is coagulated but not yet completely dried, considerably more protein residues remained on the test specimens after cleaning than after longer standing times. CONCLUSION: There is a timeframe for the removal of blood residues in which optimum cleaning results can be expected. As a consequence, there are also standing times that are disadvantageous for reprocessing. Based on the experimental data, it was deduced that this optimum time is either directly after contamination or in the range of >3 h and

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DesiccationTime FactorsAnimalsSheepBloodDisinfectionHumansDecontaminationEquipment ContaminationEquipment and Supplies

Stichwörter der Autor:innen

Blood residueDrying bloodProcessingReprocessingSurgical instrumentsTest methodology

Autor:innen und Institutionen

  • Chemische Fabrik Dr. Weigert GmbH & Co. KG, Hamburg, Germany. Electronic address: Bastian.Wulff@drweigert.de.
  • Chemische Fabrik Dr. Weigert GmbH & Co. KG, Hamburg, Germany.

Zitieren

APA

Wulff, B. R., Lohse, S., & Tschoerner, M. (2024). Influence of drying time on the removal of blood from medical devices. Journal of Hospital Infection, 152, 156-163. https://doi.org/10.1016/j.jhin.2024.07.014

Vancouver

Wulff BR, Lohse S, Tschoerner M. Influence of drying time on the removal of blood from medical devices. Journal of Hospital Infection. 2024;152:156-163. doi:10.1016/j.jhin.2024.07.014

BibTeX
@article{Wulff2024,
  author = {Wulff, B R and Lohse, S and Tschoerner, M},
  title = {Influence of drying time on the removal of blood from medical devices},
  journal = {Journal of Hospital Infection},
  year = {2024},
  volume = {152},
  pages = {156--163},
  doi = {10.1016/j.jhin.2024.07.014}
}
Kostenlos starten →