Effect of dry eye on the reliability of keratometry for cataract surgery planning
Journal Français d'Ophtalmologie · 2024-02 · 47 (2) · 103999
DOI: 10.1016/j.jfo.2023.04.016 ↗Kurz gefasst
Kontrollierte klinische Studie in der Zeitschrift Journal Français d'Ophtalmologie, 2024-02. Verfasst von F Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliated to Shanxi Medical University, Shanxi Eye Hospital, 030002 Taiyuan, China. Electronic address: yangfen2005@163.com. Hauptthemen laut MEDLINE: Cataract Extraction, Cataract, Dry Eye Syndromes, Lenses, Intraocular. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This study aimed to evaluate the effects of dry eye on the reproducibility of keratometry (K) measurements in patients presenting for cataract surgery. METHODS: A non-randomized controlled clinical study was performed. Eighty-three eyes of eighty-three patients with cataracts who were enrolled in our hospital from March 2020 to July 2020 were studied. The mean non-invasive tear film break-up time (NIBUT), corneal fluorescein staining score, and ocular surface disease (OSD) SPEED II questionnaire were measured and recorded prior to surgery, and the patients were assigned to a "dry eye" group (n=35) or a "non-dry eye" group (n=48). The K of the patients was measured twice by a Tomey OA-2000 (an average of three times each). The difference of the mean K (ΔKm) and astigmatism vector (ΔKvector) between the two measurements was calculated. The ΔKm and ΔKvector between the two groups were compared. The relationship between the measurement parameters of dry eyes and the accuracy of the preoperative K values was analyzed. RESULTS: ΔKm was 0.09 D [0.03; 0.19] in the non-dry eye control group and 0.28 D [0.18; 0.50] in the dry eye group, with a statistical difference between the two groups (P=0.005). The ΔKvector of the non-dry eye control group was 0.22 D [0.14; 0.42], and that of the dry eye group was 0.50 D [0.28; 1.06]. There was a significant difference between the two groups (P=0.010). Between the two groups, the percentage of the ΔKm and ΔKvector values greater than 0.5 D were statistically different (P 5s and NIBUT≤5s (P=0.537). There was no significant difference in ΔKm between groups≥2 and
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Affiliated to Shanxi Medical University, Shanxi Eye Hospital, 030002 Taiyuan, China. Electronic address: yangfen2005@163.com.
- Changzhi Aier Eye Hospital, Department of ophthalmology, 046000 Changzhi, China.
- Affiliated to Shanxi Medical University, Shanxi Eye Hospital, 030002 Taiyuan, China.
Zitieren
APA
Yang, F., Yang, L., Ning, X., Liu, J., & Wang, J. (2024). Effect of dry eye on the reliability of keratometry for cataract surgery planning. Journal Français d'Ophtalmologie, 47(2), 103999. https://doi.org/10.1016/j.jfo.2023.04.016
Vancouver
Yang F, Yang L, Ning X, Liu J, Wang J. Effect of dry eye on the reliability of keratometry for cataract surgery planning. Journal Français d'Ophtalmologie. 2024;47(2):103999. doi:10.1016/j.jfo.2023.04.016
BibTeX
@article{Yang2024,
author = {Yang, F and Yang, L and Ning, X and Liu, J and Wang, J},
title = {Effect of dry eye on the reliability of keratometry for cataract surgery planning},
journal = {Journal Français d'Ophtalmologie},
year = {2024},
volume = {47},
number = {2},
pages = {103999},
doi = {10.1016/j.jfo.2023.04.016}
}
EUVIMED